22
(6) 3-WIRE CONDUIT INSTALLATION
(A)
Loosen the 3 lower terminal screws from the termi-
(B)
Skip to Step 8 and proceed with the installation.
(7) 4-WIRE CONDUIT INSTALLATION
(A)
(B)
(C)
Proceed to Step 8.
(8) REPLACE THE WIRE COVER
Replace the wire cover on the range back by sliding its two lower retaining tabs into the slots and replacing the screw
removed earlier. Make sure that no wires are pinched between the cover and the range back.
Block
for terminals
Cable
points
Cable tube
(conduit)
Before
After
Block for
electrical
terminals
Cut and remove
the plate to land
Neutral terminal
Landing plate
Tips of
cables
Earthing
screw
Grounding
plate
Support
INSTALLATION INSTRUCTIONS
ELECTRICAL CONNECTIONS (CONT.)
nal block. Insert the center bare wire (white/ neu-
tral) tip through the bottom center terminal block
opening. On certain models, the wire will need to
be inserted through the ground strap opening and
then into the bottom center block opening. Insert
the two side bare wire tips into the lower left and
the lower right terminal block openings. Tighten the
screws until the wire is firmly secure (approximately
20 inch-lbs.).
NOTE: ALUMINUM WIRING:
Aluminum building wire may be used but it must be
rated for the correct amperage and voltage to
make connection. Connect wires according to this
Step 6 or Step 7 depending on number of wires.
Wire used, location and enclosure of splices, etc.,
must conform to good wiring practices and local
codes.
Loosen the three lower terminal screws from the
terminal block. Remove the ground screw and
ground plate and retain them.
Cut and discard the ground strap.
DO NOT DISCARD ANY SCREWS.
Insert the ground bare wire tip between the range
frame and the ground plate (removed earlier) and
secure it in place with the ground screw (removed
earlier). Insert the bare wire (white/neutral) tip
through the bottom center of the terminal block
opening. Insert the two side bare wire tips into the
lower left and the lower right terminal block open-
ings. Tighten the screws until the wire is firmly secure
(approximately 20 inch-lbs.).
Wire used, location and enclosure of splices, etc.,
must conform to good wiring practices and local
codes.
Block for
electrical
terminals
Support
Summary of Contents for DER202