Installation Instructions

Fig. 1

INSTALLATION
HARDWARE

LOCATION

A)

This room air conditioner is designed to fit easily into a single or double

hung window. However, since window designs vary, it may be
necessary to make some modifications for safe, proper installation.

B)

Make sure window and frame are structurally sound and free from dry

and rotted wood.

C)

For maximum efficiency, install the air conditioner on a side of the

house or building which favours more shade than sunlight. If the unit is
in direct sunlight, it is advisable to provide an awning over the unit. 

D)

Provide sufficient clearance around the cabinet to allow for ample air

circulation through the unit 

(See Fig. 2)

. The rear of the unit should be

outdoors and not in a garage nor inside a building. Keep unit as far
away as possible from obstacles/obstructions and at least 30” above
the floor or ground. Curtains and other objects within a room should be
prevented from blocking the air flow. 

E)

Be certain the proper electrical outlet is within reach of the installation.

Use only a single outlet circuit rated at 15 amps. All wiring should be in
accordance with local and national electrical codes.

F)

DO NOT install unit where leakage of combustible gas is suspected.

Your air conditioner may fail to operate in air containing oils (including
machine oils), sulfide gas, near hot springs, etc. 

NOTE:

Your unit is designed to evaporate condensation under normal

conditions. However, under extreme humidity conditions, excess conden-
sation may cause basepan to overflow to the outside. The unit should be
installed where condensation run-off cannot drip on pedestrains or neigh-
boring properties.

5

3/4in. (19.1mm)
screws (7)

Safety Lock (1)

3/8in. (9.5mm) screws
(4) *Factory installed

on some models

“L” Shaped  
mounting
bracket (1)

* Factory installed

on some models

Sash bracket (2)

Adhesive
Foam Seal(1)

Side Curtain LH (1)

Side Curtain RH (1)

Summary of Contents for DAC5111M

Page 1: ...ted Ontario Canada N1H 6Z9 Danby Products Inc Findlay Ohio USA 45840 Model Mod le Modelo Owner s Use and Care Guide Guide d utilisation et soins de Propri taire AIR CONDITIONER CLIMATISEUR V1 11 10 DM...

Page 2: ...ation initiale de ce produit CLIMATISEUR Guide d utilisation et d entretien Bienvenue Consignes de S curit Importantes Caract ristiques Installation Consignes d utilisation Soins et Entretien D pannag...

Page 3: ...iance For easy reference may we suggest you attach a copy of your sales slip receipt to this page along with the following information located on the manufacturers nameplate on side of the unit NOTE T...

Page 4: ...gh the power cord plug when plugged into a matching wall outlet If you are not sure whether your wall outlet is properly grounded please consult a qualified electrician 5 The wall outlet must match th...

Page 5: ...FIlter Exterior Air Inlet Cabinet Interior Air Inlet Control Panel Interior Air Outlet Installation Instructions CAUTION Because the compressor is located on the controls side of the unit left side t...

Page 6: ...30 above the floor or ground Curtains and other objects within a room should be prevented from blocking the air flow E Be certain the proper electrical outlet is within reach of the installation Use...

Page 7: ...Cabinet Extend the shutter from the shutter frame and slide it into the shutter tabs on the side channel of the air conditioner as shown in Fig 4 Slide the shutters into the top L Shaped and bottom U...

Page 8: ...the frames to the window sash using one 3 4 screw on each side and one in the L shaped mounting bracket Fig 5 Secure the shutter clamp on each side of the lower shutter and secure to window sill using...

Page 9: ...t days Once room is cooled reduce setting to LOW COOL OFF shuts down the unit completely NOTE Always allow 3 minutes before switching from one mode to another THERMOSTAT The thermostat automatically c...

Page 10: ...y hand in warm water Dry thoroughly before re installing CLEANING AIR FILTER 1 Use a vacuum cleaner with soft brush attachment 2 Wash the filter in lukewarm water below 40 C 104 F To get best results...

Page 11: ...utside Hot and humid weather Condensation run off is normal under these conditions 6 Water dripping inside Unit is not properly angled to allow water to drain outside Unit must be installed on an angl...

Page 12: ...authorized distributors and all other warranties conditions representations or guarantees including any warranties conditions representations or guarantees under any Sale of Goods Act or like legisla...

Page 13: ...uivants fournis sur la plaque signal tique du fabricant sur le sur le c t de l unit Vous aurez besoin de ces renseignements si vous contactez un repr sentant du Service la client le REMARQUE CET APPAR...

Page 14: ...dans une prise murale qui lui correspond Si vous n tes pas certain que votre prise de courant murale est mise la masse ad quatement veuillez consulter un lectricien qualifi 5 La prise murale doit corr...

Page 15: ...xternes sont suffisamment froides placer le climatiseur hors de service et utiliser le MODE DE VENTILATEUR la position HAUTE MOYENNE ou BAS Ceci fait circuler l air l int rieur de la pi ce pour fourni...

Page 16: ...auvent pour prot ger l unit D Laissez suffisamment d espace libre autour du caisson pour permettre une ample circulation d air travers l appareil Voir Fig 2 L arri re de l appareil doit donner sur l...

Page 17: ...e de canaux sup rieur sur le caisson Pr install sur certain mod les Canal sup rieur en forme de L Installez le canal en forme de L au dessus du caisson tel que montr la Fig 3 un utilisant quatre 4 vis...

Page 18: ...s volets compl tement de chaque c t et fixez le haut des structures au cadre de la fen tre en utilisant une vis de 3 4 po et une rondelle de s curit sur chaque c t Fig 5 Coupez la bande mousse adh sif...

Page 19: ...erme le circulation compl tement REMARQUE Il faut toujours attendre 3 minutes avant de passer d un r glage un autre THERMOSTAT Le thermostat contr le compl tement le cycle de refroidissement compresse...

Page 20: ...FILTRE AIR 1 Utilisez un aspirateur de poussi re muni d une brosse douce 2 Lavez le filtre dans de l eau ti de de moins de 40 C 104 F Pour obtenir de meilleurs r sultants lavez avec une eau savonneus...

Page 21: ...nt de la condensation est normal quand le temps est chaud et humide Ajoutez un tube flexible pour r acheminer l coulement de l eau 6 De l eau s goutte l int rieur L appareil n est pas inclin ad quatem...

Page 22: ...repr sentations en vertu de toute loi r gissant la vente de produits ou de toute autre l gislation ou r glement semblables En vertu de la pr sente Danby ne peut tre tenue responsable en cas de blessu...

Page 23: ...call the TOLL FREE NUMBER When requesting service or ordering parts always provide the following information Product Type Model Number Part Number Part Description CLIMATISEUR Le num ro de mod le se...

Reviews: