background image

Important Safety Information

READ AND FOLLOW ALL SAFETY INSTRUCTIONS

SAVE THESE INSTRUCTIONS!

Information on servicing
1.  Checks to the area: 

Prior to beginning work on systems containing fl ammable refrigerants, safety 

checks are necessary to ensure that the risk of ignition is minimized. For repair to the refrigerating 
system, the following precautions shall be complied with prior to conducting work on the system.

2. Work procedure: 

Work shall be undertaken under a controlled procedure so as to minimize the risk of 

a fl ammable gas or vapour being present while the work is being performed.

3.  General work area: 

All maintenance staff and others working in the local area shall be instructed on 

the nature of work being carried out. Work in confi ned spaces shall be avoided. The area around the 
work space shall be sectioned off. Ensure that the conditions within the work area have been made safe 
by removing all fl ammable material.

4.  Checking for the presence of refrigerant:

 The area shall be checked with an appropriate refrigerant 

detector prior to and during work to ensure the technician is aware of potentially fl ammable 
atmospheres. Ensure that the leak detection equipment being used is suitable for use with fl ammable 
refrigerants, i.e. non-sparking, adequately sealed and intrinsically safe.

5.  Presence of fi re extinguisher:

 If any hot work is to be conducted on the refrigeration equipment or 

any associated parts, appropriate fi re extinguishing equipment shall be available to hand. Have a dry 
powder or C0

2

 fi re extinguisher adjacent to the work area.

6.  No ignition sources: 

No person carrying out work in relation to a refrigeration system which involves 

exposing any pipe work that contains or has contained fl ammable refrigerant shall use any sources 
of ignition in such a manner that it may lead to risk of fi re or explosion. All possible ignition sources 
including cigarette smoking, should be kept suffi ciently far away from the site of installation, repairing, 
removing and disposal during which fl ammable refrigerant can possibly be released to the surrounding 
space. Prior to work taking place, the area around the equipment is to be surveyed to make sure there 
are no fl ammable hazards or ignition risks. No smoking signs shall be displayed.

7. Ventilated area: 

Ensure that the area is in the open or that it is adequately ventilated before breaking 

into the system or conducting any hot work. A degree of ventilation shall continue during the period 
that the work is carried out. The ventilation should safely disperse any released refrigerant and 
preferable expel it externally into the atmosphere.

8.  Checks to the refrigeration equipment: 

Where electrical components are being changed, they shall 

be fi t for the purpose and to the correct specifi cation. At all times the manufacturer’s maintenance and 
service guidelines shall be followed. If in doubt consult the manufacturer’s technical department for 
assistance. The following checks shall be applied to installations using fl ammable refrigerants:
•  The charge size is in accordance with the room size within which the refrigerant containing parts 

are installed. 

•  The ventilation machinery and outlets are operating adequately and are not obstructed.
•  If an indirect refrigerating circuit is being used, the secondary circuit shall be checked for the 

presence of refrigerant.

•  Marking to the equipment continues to be visible and legible. Markings and signs that become 

illegible must be corrected.

•  Refrigeration pipe or components are installed in a position where they are unlikely to be exposed 

to any substance which may corrode refrigerant containing components, unless the components are 
constructed of materials which are inherently resistant to being corroded or are suitable protected 
against being corroded.

9.  Checks to electrical devices: 

Repair and maintenance to electrical components shall include initial 

safety checks and component inspection procedures. If a fault exists that could compromise safety, then 
no electrical supply shall be connected to the circuit until it is satisfactorily dealt with. If the fault cannot 
be corrected immediately but it is necessary to continue operation, an adequate temporary solution 
shall be used. This shall be reported to the owner of the equipment so all parties are advised. Initial 
safety checks shall include:
•  That capacitors are discharged. This shall be done in a safe manner to avoid possibility of sparking.
•  That no live electrical components and wiring are exposed while charging, recovering or purging 

the system.

•  That there is continuity of earth bonding.

Summary of Contents for DAC080B5WDB

Page 1: ...Marca comerciales de Danby Products Danby Products Limited Guelph Ontario Canada N1H 6Z9 Danby Products Inc Findlay Ohio U S A 45840 www Danby com AIR CONDITIONER Owner s Manual 1 18 CLIMATISEUR Manu...

Page 2: ...TH WARRANTY EXTENSION after lling out a product survey at www danby com support product registration Need Help 1 Read your Owner s Manual for installation help troubleshooting and maintenance assistan...

Page 3: ...t If the refrigerant leaks and is exposed to an external ignition source there is a risk of re CAUTION Shows that the operation manual should be read carefully CAUTION Shows that service personnel sho...

Page 4: ...uch as a bathroom or laundry room Too much exposure to water can cause electrical components to short circuit Do not install the unit in a location that may be exposed to combustible fas as this could...

Page 5: ...ditioner with any solid state speed control device The appliance shall be installed in accordance with national wiring regulations Contact the authorized service technician for repair or maintenance o...

Page 6: ...zes their competence to handle refrigerants safely in accordance with an industry recognized assessment speci cation Servicing shall only be performed as recommended by the manufacturer Maintenance an...

Page 7: ...ards or ignition risks No smoking signs shall be displayed 7 Ventilated area Ensure that the area is in the open or that it is adequately ventilated before breaking into the system or conducting any h...

Page 8: ...ect rating Replace components only with parts speci ed by the manufacturer Other parts may result in the ignition of refrigerant in the atmosphere from a leak Cabling Check that cabling will not be su...

Page 9: ...complete if not already labeled Extreme care shall be taken not to over ll the refrigeration system Prior to recharging the system it shall be pressure tested with OFN The system shall be leak tested...

Page 10: ...t shall be in good working order with a set of instructions concerning the equipment that is at hand and shall be suitable for the recovery of ammable refrigerants In addition a set of calibrated weig...

Page 11: ...ce should be installed where condensation cannot drip on pedestrians or neighboring properties Provide suf cient clearance around the appliance to allow ample air circulation The rear of the appliance...

Page 12: ...dow sash down until it rests just behind the front ange of the L shaped mounting bracket Expand the side curtains on each side and secure the top of the frames to the window sash using one 13 mm 1 2 s...

Page 13: ...decrease buttons for 3 seconds to change between C and F 4 Power Button Used to turn the appliance on or off A Energy saver mode indicator B Wireless connection indicator C Cool mode indicator D Fan...

Page 14: ...bstruction between the receiver and remote may cause signal interference limiting the ability to program the main unit REMOTE CONTROL 1 Power Button Used to turn the appliance on or off 2 Mode Button...

Page 15: ...pliance could void the user s authority to operate the equipment This appliance complies with Part 15 of the FCC Rules and license exempt RSS standards Operation is subject to the following conditions...

Page 16: ...Visit https www danby com support apps to download the application and learn about its operation 15 SHORTCUT FUNCTION The shortcut function is only available on the remote control It can be used to se...

Page 17: ...ide the appliance Ensure the lter is clean and dry Store the appliance covered in a dry location Note When installing or removing the appliance from the window ensure that caution is taken to prevent...

Page 18: ...utdoor temperatures are below 18 3 C 65 F frost may form when the air conditioner is in cooling mode Switch the air conditioner to fan only mode until the frost melts Air conditioner will not operate...

Page 19: ...669 Findlay Ohio U S A 45840 Telephone 419 425 8627 FAX 419 425 8629 04 09 1 800 263 2629 Warranty Service In home Transportation charges to and from the service location are not protected by this war...

Page 20: ...rempli une enqu te sur les produits l adresse www danby com support product registration Besoin d assistance 1 Lisez votre manuel du propri taire pour obtenir de l aide l installation au d pannage et...

Page 21: ...ne source d allumage externe il existe un risque d incendie MISE EN GARDE Indique que le manuel d utilisation doit tre lu attentivement MISE EN GARDE Indique que le personnel de service doit manipuler...

Page 22: ...elle qu une salle de bain ou une buanderie Une exposition excessive l eau peut provoquer un court circuit des composants lectriques N installez pas l unit dans un endroit qui pourrait tre expos des fa...

Page 23: ...contr le de vitesse semi conducteurs L appareil doit tre install conform ment aux r glementations nationales en mati re de c blage Contactez le technicien de service agr pour la r paration ou l entret...

Page 24: ...rig rants en toute s curit conform ment une sp ci cation d valuation reconnue par l industrie L entretien ne doit tre effectu que selon les recommandations du fabricant La maintenance et les r paratio...

Page 25: ...lit ou de risque d in ammation Aucun signe de fumer ne doit tre af ch 7 Zone ventil e Assurez vous que la zone est l air libre ou qu elle est correctement ventil e avant de p n trer dans le syst me ou...

Page 26: ...es par le fabricant D autres pi ces peuvent provoquer l in ammation de r frig rant dans l atmosph re par une fuite Le c blage V ri ez que le c blage ne sera pas soumis l usure la corrosion une pressio...

Page 27: ...st me de r frig ration Avant de recharger le syst me il doit tre test sous pression avec OFN Le syst me doit tre soumis un test d tanch it la n du chargement mais avant la mise en service Un contr le...

Page 28: ...ipement disponible et doit tre adapt la r cup ration des r frig rants in ammables En outre un jeu de balances talonn es doit tre disponible et en bon tat de fonctionnement Les exibles doivent tre comp...

Page 29: ...s le mur Assurez vous que la fen tre et le cadre sont structurellement sains et exempts de bois sec ou pourri Installez le climatiseur dans une fen tre sur un c t du b timent qui favorise plus d ombre...

Page 30: ...up rieure jusqu ce qu il repose juste derri re la bride avant du support de montage en forme de L D veloppez les rideaux lat raux de chaque c t et xez le haut des cadres au ch ssis de fen tre l aide d...

Page 31: ...d alimentation Utilis pour allumer ou teindre l appareil A Indicateur de mode d conomie d nergie B Indicateur de connexion sans l C Indicateur de mode froid D Indicateur de mode de ventilation E Af c...

Page 32: ...de programmer l unit principale T L COMMANDE 1 Bouton d alimentation Utilis pour allumer ou teindre l appareil 2 Bouton de mode Utilis pour choisir le mode de fonctionnement 3 Bouton du ventilateur Ut...

Page 33: ...annuler le droit de l utilisateur faire fonctionner l quipement Cet appareil est conforme la partie 15 des r gles FCC et aux normes RSS sans licence Son utilisation est soumise aux deux conditions sui...

Page 34: ...l Rendez vous sur https www danby com support apps pour t l charger l application et d couvrir son fonctionnement FONCTION DE RACCOURCI La fonction de raccourci est uniquement disponible sur la t l c...

Page 35: ...viter les blessures aux personnes ou les dommages mat riels ou l appareil DISPOSITION V ri ez la conformit r glementaire locale concernant l limination approuv e et s re de cet appareil FILTRE AIR Tou...

Page 36: ...se former lorsque le climatiseur est en mode refroidissement Mettez le climatiseur en mode ventilateur uniquement jusqu ce que le givre fonde Le climatiseur ne fonctionnera pas La che n est pas compl...

Page 37: ...rts par la pr sente garantie et doivent tre acquitt s par l acheteur Pendant les premiers vingt quatre 24 mois toutes les pi ces fonctionnelles de ce produit qui s av rent d fectueuses seront r par es...

Page 38: ...MESES despu s de completar una encuesta sobre el producto en www danby com support product registration Necesitas ayuda 1 Lea el manual del propietario para obtener ayuda con la instalaci n resoluci...

Page 39: ...l de servicio debe manipular este equipo con referencia al manual de instalaci n PRECAUCI N Muestra que la informaci n est disponible como el manual de operaci n o el manual de instalaci n PRECAUCI N...

Page 40: ...a o o un lavadero Demasiada exposici n al agua puede provocar un cortocircuito en los componentes el ctricos No instale la unidad en un lugar que pueda estar expuesto a combustibles ya que esto podr a...

Page 41: ...ontrol de velocidad de estado s lido El aparato debe instalarse de acuerdo con las regulaciones nacionales de cableado Comun quese con el t cnico de servicio autorizado para la reparaci n o el manteni...

Page 42: ...eci caci n de evaluaci n reconocida por la industria El servicio solo se realizar seg n lo recomendado por el fabricante El mantenimiento y las reparaciones que requieran la asistencia de otro persona...

Page 43: ...riesgos de ignici n Se exhibir n carteles de no fumar 7 rea ventilada aseg rese de que el rea est al aire libre o que est adecuadamente ventilada antes de ingresar al sistema o realizar cualquier tra...

Page 44: ...solo con piezas especi cadas por el fabricante Otras partes pueden provocar la ignici n del refrigerante en la atm sfera debido a una fuga Cableado Compruebe que el cableado no est sujeto a desgaste...

Page 45: ...tado Se debe tener mucho cuidado de no sobrecargar el sistema de refrigeraci n Antes de recargar el sistema se someter a prueba de presi n con OFN El sistema debe ser probado contra fugas al nalizar l...

Page 46: ...ue se encuentra a mano y debe ser adecuado para la recuperaci n de refrigerantes in amables Adem s un conjunto de balanzas calibradas estar disponible y en buen estado de funcionamiento Las mangueras...

Page 47: ...Aseg rese de que la ventana y el marco est n estructuralmente rmes y libres de madera seca o podrida Instale el aire acondicionado en una ventana en un costado del edi cio que favorezca m s sombra que...

Page 48: ...hasta que descanse justo detr s de la brida delantera del soporte de montaje en forma de L Expanda las cortinas laterales en cada lado y asegure la parte superior de los marcos al marco de la ventana...

Page 49: ...nte 3 segundos para cambiar entre C y F 4 Bot n de encendido Se utiliza para encender o apagar el aparato A Indicador de modo de ahorro de energ a B Indicador de conexi n inal mbrica C Indicador de mo...

Page 50: ...r la temperatura establecida Mantenga presionados los botones de aumento y disminuci n durante 3 segundos para cambiar entre C y F 12 Pantalla LED Muestra la temperatura con gurada y el ajuste del tem...

Page 51: ...po Este aparato cumple con la Parte 15 de las Reglas de la FCC y los est ndares RSS exentos de licencia El funcionamiento est sujeto a las siguientes condiciones 1 Este dispositivo no puede causar int...

Page 52: ...aplicaci n y obtener informaci n sobre su funcionamiento FUNCI N DE ACCESO DIRECTO La funci n de acceso directo solo est disponible en el control remoto Se puede utilizar para establecer un ajuste fa...

Page 53: ...conformidad reglamentaria local con respecto a la eliminaci n aprobada y segura de este electrodom stico FILTRO DE AIRE Aproximadamente cada dos semanas la luz indicadora del ltro en el panel de contr...

Page 54: ...onador de aire est en modo de refrigeraci n Cambie el aire acondicionado al modo de solo ventilador hasta que la escarcha se derrita El aire acondicionado no funcionar El enchufe no est completamente...

Page 55: ...sulte defectuosa incluyendo cualquier sistema sellado ser reparado o reemplazado a opci n del fabricante sin cargo para el comprador original P ngase en contacto con el distribuidor donde adquiri el e...

Page 56: ...___________________ __________________________________________________________________________________________ _________________________________________________________________________________________...

Reviews: