Regen circuit: technical data
SERVOSTAR
Supply
voltage
Rated data
DIM
601 - 603
606 - 620
3 x 230 V
Upper switch-on level of regen circuit
V
400 - 430
Switch-off level of regen circuit
V
380 - 410
Overvoltage F02
V
450
Continuous power of regen circuit (R
Bint
)
W
80
200
Continuous power of regen circuit (R
Bext
) max.
kW
0.25
0.75
Pulse power, internal (R
Bint
max. 1s)
kW
2.5
5
Pulse power, external (R
Bext
max. 1s)
kW
5
External regen resistor
W
33
3 x 400 V
Upper switch-on level of regen circuit
V
720 - 750
Switch-off level of regen circuit
V
680 - 710
Overvoltage F02
V
800
Continuous power of regen circuit (R
Bint
)
W
80
200
Continuous power of regen circuit (R
Bext
) max.
kW
0.4
1.2
Pulse power, internal (R
Bint
max. 1s)
kW
8
16
Pulse power, external (R
Bext
max. 1s)
kW
16
External regen resistor
W
33
3 x 480 V
Upper switch-on level of regen circuit
V
840 - 870
Switch-off level of regen circuit
V
800 - 830
Overvoltage F02
V
900
Continuous power of regen circuit (R
Bint
)
W
80
200
Continuous power of regen circuit (R
Bext
) max.
kW
0.5
1.5
Pulse power, internal (R
Bint
max. 1s)
kW
10.5
21
Pulse power, external (R
Bext
max. 1s)
kW
21
External regen resistor
W
33
Suitable external regen resistors can be found in our accessories manual.
SERVOSTAR
®
601...620 Product Manual
23