ENG-AA+AE-jord-DK 2019/20.12.2007
INSTALLATION ON CONCRETE OR BRICK WALL:
➊
Attach the template (Fig. 1) to the wall with tape ensuring that it is level.
➋
Mark and drill holes "A". Drill holes to fit plugs for 8 mm screws.
➌
Insert plugs and secure the
dryer to the wall with 8 mm
screws.
INSTALLATION ON WOODEN
OR PLASTER WALL:
➊
Attach the template (Fig. 1) to
the wall with tape ensuring
that it is level.
➋
Mark and drill holes "A".
➌
Secure the dryer with 8 mm
screws for relevant wall type.
Use plugs for plaster walls.
INSTALLATION HEIGHTS:
From floor to the lower edge of the dryer:
mounted as
hand dryer
mounted as
hair dryer
Adults
1150 mm (45")
1900 mm (75")
Children
950 mm (38")
1700 mm (67")
Disabled
950 mm (38")
1550 mm (61")
If multiple dryers are installed in line, the distance between each dryer must be
minimum 600 mm (24"), measured from the centre of each dryer. Avoid
installation directly above sink, tabletop or other reflective surfaces. If this is
inevitable, it may be necessary to adjust the activation distance.
MAINS CONNECTION:
➊
When connecting directly to the fixed installation wiring via fixed cable or
terminal box in the wall behind the dryer, the cable must be fed through
hole "B" (Fig. 1) in the base plate and connected to the terminal block "E".
Connect by means of three leads of min. 1.5 mm
2
cross-section per lead,
150 mm long (7 mm of which stripped).
➋
If installation as described in point
➊
is not possible, ensure fixed
installation via contact breaker by feeding a loose, insulated cable through
hole "C" at the bottom of the base plate, through tensile relief strap "D" for
connection to terminal block "E". Apply three-core
cable with earth wire,
each lead min. 1.5 mm
2
cross section; maximum cable length: 1.5 m.
Before securing the housing, remove the small relief at the bottom of the
housing with cutting nippers and a file, ensuring that the hole is deburred
and has no sharp edges.
NB:
For dryers
with stainless steel housings, point
➊
is the only installation option.
TESTING AND ADJUSTMENT - PUSHBUTTON MODEL:
The adjustable drying time is factory pre-set to approx. 30 seconds. The
adjustment screw in the timer increases the cycle when turned clockwise and
decreases when turned anti-clockwise.
If the dryer is installed as a hair dryer, the drying cycle may be set to the
maximum time - approx. 170 seconds.
Do not attempt to dismantle the magnet attached to the inside end of the
pushbutton - not even to test run the dryer.
TESTING AND ADJUSTMENT – ELECTRONIC MODEL:
The activation distance is factory pre-set to max. 200 mm measured from the
air outlet. The activation distance can be increased by turning the adjusting
screw on the timer clockwise, and decreased by turning the adjusting screw
anti-clockwise.
The dryer starts automatically when hands are placed in the activation area
and stops automatically 4 seconds after hands are removed.
Never test run dryers without the housing being fully secured in its place.
IMPORTANT
• If the dryer is installed as a hair dryer, it must be mounted out of reach
of persons using shower or bath tub.
• The dryer must be properly earthed. When connecting directly to the
fixed installation wiring via fixed installation circuit breaker, when
switched off, the total distance of break in the circuit breaker must be
min. 3 mm.
•
Remove the polystyrene protection block located inside the dryer
underneath the motor before switching the dryer on
.
Fig. 1