WARNING

• All units must be equipped with a 3-wire service. Connect the ground wire according  
   to the instructions.

• This product must be installed only by qualified persons. Use 2.0mm

2

 (AWG) NO.14 wiring.

• Turn off the power to the unit before servicing or cleaning. All wires must be disconnected.
• Incorrect installation, defect power cords, or failure to properly ground unit could result in  
   electrical shock or life-threatening injuries.

NOTE

 

We do not recommend to install this product above a washbasin. Installation above reflective 

surfaces will cause the hand dryer to start on its own. This product is suitable for indoor use 

only.

Type Y connection: If the power supply cord is damaged, it must be replaced immediately. 

Only qualified persons shall be permitted to replace the cord to avoid a hazard. Disconnect 

the electricity supply cord according to instructions.

This product is not intended for use by persons (inclusive children) with reduced physical, 

sensory or mental capabilities, or lack of experience and knowledge, unless they are 

supervised or have been given instruction concerning use of the product by a person 

responsible for their safety.

Children should be supervised to ensure this product is used correctly.

GENERAL SAFETY INFORMATION

CIRCUIT DIAGRAM

!

Circuit Board Module 

L

N

G/Y

Br

own

Blue

Black

Black

Only 110/120V

Mot
or

 Wi
th 

Thermal Switc

h 2A

Red

Hea
ter 
with Thermo-fu

se

White

VR 

FOR SPEED

VR 

FOR SENSOR

Sensor module

Transistor

Power Switch

Thermostat

N

MO2HE2

MO1 HE1

L

Summary of Contents for 250-251-254

Page 1: ...USER MANUAL TURBO LOW NOISE HAND DRYER Model 346 347 348 250 251 254 ...

Page 2: ...arm air speed output 7 Heating element switch 7 Adjustment of sensor range 7 Troubleshooting and corrective actions 8 Symptoms and corrective actions of first time installed hand dryers 8 Symptoms and corrective actions of used hand dryers 8 Parts list 9 TABLE OF CONTENTS This product should not be disposed of with general household waste This product must be reused if possible Contact your local ...

Page 3: ...700W adjustable Heating element protection Auto resetting thermostat turns circuit off at 85 C thermal fuse turns off at 142 C Drying time 15 seconds Stand by power 0 3 0 4W Sensor type Infrared self adjusting Sensor range 100 230 mm adjustable Standard 170mm 20mm Protection timer 60 seconds auto shut off IP Class IP31 or IP33 option Insulation class Class 1 Net weight 5 5 kg Gross weight 6 1 kg P...

Page 4: ...tion If the power supply cord is damaged it must be replaced immediately Only qualified persons shall be permitted to replace the cord to avoid a hazard Disconnect the electricity supply cord according to instructions This product is not intended for use by persons inclusive children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they are supervised...

Page 5: ...t NEUTRAL to terminal N C Connect GROUND to terminal Make sure the main breaker is turned off Installation must be carried out by a qualified person in accordance with standards applicable in the country where the equipment is to be installed Place template against the wall at desired height see mounting height recommendations and mark location of 4 mounting holes and the wire service entry Note I...

Page 6: ...are worn they must be replaced The estimated lifespan for carbon brushes is 580K activations Do not soak Use a damp cloth and mild cleaning solution Never use cleaning detergents with an abrasive effect Replace the cover Do not overtighten the screws USER GUIDE No touch operation Shake excess water from hands Place hands under the outlet to start operation Rub hands lightly and rapidly Stops autom...

Page 7: ...terclockwise to decrease air speed SENSOR RANGE ADJUSTMENT The sensor range adjustable between 100mm and 230mm Standard range 170mm 20mm Clockwise To increase sensor activation range Counterclockwise To decrease sensor activation range The sensor activation range should be adjusted to its environments e g light and distance to the bottom of the sink Note Do not overturn the sensivity adjustment ...

Page 8: ...un First ensure that the breaker supplying the dryer is opera tional If it is disconnect the power and remove the cover Replace PCB and IR sensor Taking suitable precaution to avoid shock hazard reconnect the power and check for vol tage on the terminal block The IR sensor detects only close range objects Ensure that there is no obstruction on or in front of the IR sensor Clean any dirt off the se...

Page 9: ...r rubber large 6 Motor 7 Motor rubber small 8 Blower housing lower 9 Heating element 10 Air outlet 11 LED panel 12 Air outlet bracket 13 Timer with IR sensor 14 Sensor bracket 15 Rubber bushing 4 reqd 16 Base plate 17 Grounding screw 18 Filter kit option 19 HEPA filter kit option 20 P clips 21 Insulation mylar 22 Terminal block 23 Sensor module ...

Page 10: ...10 DAN DRYER A S Alsikevej 8 DK 8920 Randers NV T 45 8641 5711 E info dandryer dk W dandryer com ...

Reviews: