Serie "LXS9"
Pagina A - 14
Rev. M - 01
>
N
IGHT
M
ODE INTERNAL TEMPERATURE SETTING
:
(Visible and programmable only with Vivilight Kit installed and “
Refrigerator
operation” other than “Food & Snack”)
This parameter allows setting the internal temperature of the vending machine when the
Night Mode
function is activated.
Settable values:
0 ÷ 50°C
.
The refrigerator temperature raising function is deactivated during the
Night-Mode
period if the parameter
is set to „
0
‟ (Zero) or to a value below the one set as standard internal temperature („
Set Std Temp 1
‟ in the
“
Refrig. Param‟s
” menu).
This parameter can also be programmed through the “
Energy Saving
” menu in the “
General Param‟s
”.
Refer to the “
Energy Saving
” section for further information on this function.
[ Default: 0°C ]
>
REFRIGERATION UNIT WORKING TEMPERATURE READING
:
(Only visible if 2
nd
refrigerator probe present)
To read the working temperature inside the refrigeration unit evaporator.
[ Read only ]
>
S
AFETY TEMPERATURE
:
(Visible and programmable only with „
Refrigerator
operation = Food & Snack‟)
To read the safety temperature for the sale of food products; see the
Overtemperature control
section
and the description of the “
ERR L09
” error message for the description.
Settable values:
0 ÷ 45°
C.
To deactivate this function, set it to
≥40°C.
[ Default: 45 °C ]
>
O
VERTEMPERATURE TIME
:
(Visible and programmable only with „
Refrigerator
operation = Food & Snack‟)
To set the time beyond which the internal temperature must not exceed the safety temperature; see the
Overtemperature control
section and the description of the “
ERR L09
” message for the description.
Settable values:
0 ÷ 1440
minutes
.
[ Default: 30 minutes]
>
R
ESTOCKING TIME
:
(Visible and programmable only with „
Refrigerator
operation = Food & Snack‟)
To set the time that is added to the overtemperature time each time restocking takes place (vending
machine turned on); see the
Overtemperature control
section for the description.
Settable values:
0 ÷
1000
minutes
.
[Default: 120 minutes]
>
C
ONNECTED PROBES
:
To read the number of refrigeration unit control probes that are connected.
[ Read only ]
Programming
Refrig. Param's
Night Mode temp.
Current value
F
Programming
Refrig. Param's
Probe 2 measure
Current value
F
Programming
Refrig. Param's
Security temper.
Current value
F
Programming
Refrig. Param's
Overtemper. time
Current value
F
Programming
Refrig. Param's
Refueling time
Current value
F
Programming
Refrig. Param's
Connected probes
Current value
F