background image

Dametric AB 

CEC-DM1 

CAN-Ethernet-Converter 

CEC-DM1 EN.docx 

June 2, 2008 

Page 2 (3) 

Table of contents 

 

1

 

GENERAL ................................................................................................................................................... 2

 

2

 

TECHNICAL SPECIFICATION ................................................................................................................... 2

 

3

 

CONNECTION DIAGRAM .......................................................................................................................... 2

 

4

 

TROUBLESHOOTING ................................................................................................................................ 3

 

5

 

CONTACT ................................................................................................................................................... 3

 

 
 

1 General 

The CEC-DM1 is a converter module between the CAN bus and the Ethernet network. 
It is used in the GMS measuring system for data exchange between the RMS/GMS units and the control 
software in a Panel PC. The IP-based protocol uses the UDP transport layer for data exchange. 
Each unit has a unique MAC-address and the configurable IP-address. The software in the Panel PC is set up 
to exchange data to a specified IP-address. 
The unit is powered with 24Vdc.  

2 Technical 

Specification 

Metso part no:

  

VAL0219209 

Supply voltage:   

24 VDC, ± 10 %. 

Power consumption:    Nominal 0.1A, Max. 0.2A. 
CAN: 

Up to 1Mbit baudrate, 4-pole jackable screw connector. 

Ethernet; 

IP-based, UDP-protocol, RJ45 connector. 

Module size:   

Height=110 mm, Width=23 mm, Depth=115 mm. 

Closure:   

Polycarbonate (30%GV), DIN-rail mounting. 

Connections:   

Plug-in screw connectors, max 2.5mm2 cable areas. 

3 Connection 

Diagram 

K1 +24VDC 

K1/1 

+24VDC 

The power supply (internally connected to K1/2) 

K1/2 

+24VDC 

The power supply (internally connected to K1/1) 

K1/3 

0VDC 

The power ground (internally connected to K1/4) 

K1/4 

0VDC 

The power ground (internally connected to K1/3) 

 

K2 CAN 

 

K2/1 

CAN-H 

CAN-interface H-signal (use twisted pair cable for CAN-H and CAN-L) 

K2/2 CAN-L 

CAN-interface 

L-signal 

K2/3 

CAN-R 

CAN-interface, connect to K2/2 for 120

 termination  

K2/4 

0VDC 

The power ground (internally connected to K1/2 and K1/3) 

 

K3 Ethernet 

 

K3 Ethernet  RJ-45 

connector 

 

Reviews: