X64 Xcelera-CL PX4 User's Manual
X64 Xcelera-CL PX4 Reference
•
45
Line Trigger Source Selection for Linescan
Applications
Linescan imaging applications require some form of external event trigger to synchronize linescan
camera exposures to the moving object. This synchronization signal is either an external trigger source
(one exposure per trigger event) or a shaft encoder source composed of a single or dual phase
(quadrature) signal. The X64 Xcelera-CL PX4
shaft encoder inputs provide additional functionality with
pulse drop or pulse multiply support.
The following table describes the line trigger source types supported by the X64 Xcelera-CL PX4 Full.
Refer to the Sapera Acquisition Parameters Reference Manual (OC-SAPM-APR00) for descriptions of
the Sapera parameters.
CORACQ_PRM_EXT_LINE_TRIGGER_SOURCE – Parameter
Values Specific to the X64-CL series
PRM Value
Active Shaft Encoder Input
0 Default
1
Use phase A
2
Use phase B
3
Use phase A & B
Summary of Contents for X64 Xcelera-CL PX4
Page 32: ...30 Installing X64 Xcelera CL PX4 X64 Xcelera CL PX4 User s Manual ...
Page 42: ...40 CamExpert Quick Start X64 Xcelera CL PX4 User s Manual ...
Page 104: ...102 Camera Link Interface X64 Xcelera CL PX4 User s Manual ...
Page 124: ...122 Glossary of Terms X64 Xcelera CL PX4 User s Manual ...