03-36-00160-03
DALSA INC.: Phone: 519-886-6000 Fax: 519-886-8023
3
www.dalsa.com
DALSA EUROPE: Phone: +49-8142-46770 Fax: +49-8142-467746
ISO 9001
PRELIMINARY
SP-11-xxx30
For product information and updates visit
www.dalsa.com
Compact Line Scan Cameras
1
19
18
36
Control & Data Connector
Mating Part:
Cable:
3M 10136-6000EC series
26AWG 100W shielded twisted pair
Pin Signal
1
SPEED
2
GAIN0
3
Future use
4
GAIN1
5
MCLK
6
PRIN
7
EXSYNC
8
BIN
9
D7
10 D6
11 D5
12 D4
13 D3
14 D2
15 D1
16 D0
17 STROBE
18 LVAL
GAIN0B
GAIN1
Pin Signal
Description
19 SPEEDB
20
21 Future use
22
B
23 MCLKB
24 PRINB
25 EXSYNCB
26 BINB
27 D7B
28 D6B
29 D5B
30 D4B
31 D3B
32 D2B
33 D1B
34 D0B
35 STROBEB
36 LVALB
Controls data rate
Controls gain
Not used: Do not connect
Controls gain
Controls master clock frequency
Exposure control
Controls line rate/exposure time
Controls pixel binning (summing)
Pixel clock; data valid on rising edge
Pixel data valid during logic high state
Default
30MHz
High
High
30MHz
Disabled
Free run
Disabled
5
4
6
2
3
1
Mating Part:
HIROSE
HR10A-7P-6S
Power Connector
Pin Signal Current
1
+5V
2
+5V
3
+15
8
4
-5V
8
5
GND
6
GND
0mA
0mA
All data and control signals use
EIA-644 (LVDS) format.
Camera meets all performance
specifications using standard
switching power supplies.
Voltage Input Tolerance:
±250mV on all supplies.
Data bits
Outputs
600mA
Notes on Operation
(for full detail, see the Camera User’s Manual)
1. All control signals are OPTIONAL and default to logic high state when unconnected.
2. Long unterminated cables can act as antennae, causing spurious inputs. DALSA recommends
tying unused inputs to known states using using differential drivers or resisitive networks.
3. Max. operating temperature is 50°C ambient.
4. Free run is disabled when the camera receives an EXSYNC edge. The camera will not free run
again until it is powered off and on again.
Figure 2. SP-11 Connector Pinouts