Camera Link Mode Configuration (Controlled by clm command)
Readout Direction (Controlled by
smm
command)
Pixel Rate
Configuration
(Controlled by sot
command)
Command
Camera Link
Configuration
Camera Link Taps
Bit
Depth
clm 21
Fu ll
8 Cam era Link tap s
w here:
1 = CCD tap 1+2
2 = CCD tap 3+4
3 = CCD tap 5+6
4 = CCD tap 7+8
5 = CCD tap 9+10
6 = CCD tap 11+12
7 = CCD tap 13+14
8 = CCD tap 15+16
8
smm 0
= CL tap 1(1-1024)
CL tap 2(1025-2048)
CL tap 3(2049-3072)
CL tap 4(3073-4096)
CL tap 5(4097-5120)
CL tap 6(5121-6144)
CL tap 7(6145-7168)
CL tap 8(7169-8192)
smm 1
= CL tap 1(8192-7169)
CL tap 2(7168-6145)
CL tap 3(6144-5121)
CL tap 4(5120-4097)
CL tap 5(4096-3073)
CL tap 6(3072-2049)
CL tap 7(2048-1025)
CL tap 8(1024-1)
sot 640
= 80 MH z
strobe (ES-80-08k80
only)
(m ax line rate
68610H z)
sot 320
= 40 MH z
strobe
(m ax line rate
37629H z)
Table 14: ES-82-04k40 Configurations
Camera Link Mode Configuration (Controlled by clm command)
Readout Direction (Controlled by
smm
command)
Pixel Rate
Configuration
(Controlled by sot
command)
Command
Camera Link
Configuration
Camera Link Taps
Bit
Depth
clm 15
Med iu m
4 Cam era Link tap s
w here:
1 = CCD tap
1+2+3+4
2 = CCD tap
5+6+7+8
3 = CCD tap
9+10+11+12
4 = CCD tap
13+14+15+16
8
smm 0
= CL tap 1(1-1024)
CL tap 2(1025-2048)
CL tap 3(2049-3172)
CL tap 4(3173-4096)
smm 1
= CL tap 1(4096-3173)
CL tap 2(3172-2049)
CL tap 3(2048-1025)
CL tap 4(1024-1)
sot 320
= 80 MH z
strobe
(m ax rate 55020H z)
sot 160
= 40 MH z
strobe
(m ax line rate
37629H z)
clm 16
Med iu m
4 Cam era Link tap s
w here:
1 = CCD tap
1+2+3+4
2 = CCD tap
5+6+7+8
3 = CCD tap
9+10+11+12
4 = CCD tap
13+14+15+16
12
smm 0
= CL tap 1(1-1024)
CL tap 2(1025-2048)
CL tap 3(2049-3072)
CL tap 4(3073-4096)
smm 1
= CL tap 1(4096-3073)
CL tap 2(3072-2049)
CL tap 3(2048-1025)
CL tap 4(1024-1)
sot 320
= 80 MH z
strobe
(m ax line rate
55020H z)
sot 160
= 40 MH z
strobe
(m ax line rate
37629H z)
Summary of Contents for Piranha ES-80-08k40-00-R
Page 22: ...Piranha ES xx User Manual 03 032 20070 02 Teledyne DALSA 22 ...
Page 88: ...Piranha ES xx User Manual 03 032 20070 02 Teledyne DALSA 88 ...
Page 102: ...Piranha ES xx User Manual 03 032 20070 02 Teledyne DALSA 102 ...
Page 104: ...Piranha ES xx User Manual 03 032 20070 02 Teledyne DALSA 104 ...