6M18 Camera User’s Manual
19
DALSA
03-32-10017-03
TTL Trigger
Input
175ns
+/- 25
Min. 10 µs
Figure 8: Trigger Timing Description
2.10 Integration Time
The minimum integration time is 10
µ
s. As with any full frame imager, the camera will continue to
integrate during read out unless externally shuttered or strobed.
2.11 Timing
The 6M18 pixel clock runs at 40 MHz, so each pixel clock cycle will be 1/40,000,000 or 25 Ns.
The following diagram and tables describe the correct timing requirements for the 6M18 camera.
Figure 9: 6M18 Timing
Table 11: HSYNC Pixel Timing
Horizontal
Binning
Mode
A
B
C
D
E
F
1x
11
26
1536
13
518
0
2x
5
16
768
4
539
0
4x
3
6
384
3
550
0
VSYNC
HSYNC
PIXEL
CLOCK
1 2 3
A
B
C
C
E
D
F
IMPORTANT:
This camera uses the
falling
falling
falling
falling
edge of the pixel
clock to register data.
Summary of Contents for Dalsa DS-4x-06M18
Page 10: ...6M18 Camera User s Manual 10 DALSA 03 32 10017 03 ...
Page 38: ...6M18 Camera User s Manual 38 DALSA 03 32 10017 03 ...
Page 40: ...6M18 Camera User s Manual 40 DALSA 03 32 10017 03 ...
Page 42: ...6M18 Camera User s Manual 42 DALSA 03 32 10017 03 V Video Timing 19 VSYNC 16 W Warranty 43 ...