14.5.2
DNI - camera control
A controllable camera (dome, PTZ camera) can be connected to the recorder via a DNI.
This allows the dome or tilt and turn head of a camera to be controlled using the recorder’s
control interface.
Interface
After connecting the DNI the serial interface must be configured accordingly. Open the
Serial
Interfaces
dialog via
Setup
>
Interfaces
>
Serial
.
Fig. 14-9:
Serial Interfaces
dialog
Ø
Select the COM port to which the DNI is connected as the
Interface
.
Ø
Set
DNI (camera control)
as the function.
Ø
Confirm with
OK
.
Protocol
The next step is to configure the DNI itself. Open the
Camera Control
dialog via
Setup
>
Interfaces
>
Camera control
.
Fig. 14-10:
Camera Control
dialog
Ø
First open the data for the DNI Network by clicking on
Read
.
Ø
Mark the relevant DNI.
Ø
Select the required
Protocol
.
Ø
Configure the DNI by clicking on
Program
.
Ø
Confirm with
OK
.