6 Installation and Commissioning
Installation and commissioning of the unit may only be carried out by qualified personnel.
WARNING
electric shock hazard
Danger of death or serious injury
Disconnect the power supply unit from the mains socket before connect-
ing the device.
In order to comply with the UL requirements, you have to use a UL-certified, limited power
source (LPS) Class 2 power supply unit.
6.1
Attaching the lens
Lens
Lens thread
Max. 5 mm
Fig. 6-1
Notice
Possible damage to the sensor
The length of the lens thread plus any protruding parts must not exceed
5 mm.
If using a C-mount lens, you have to screw a C-/CS-mount adapter ring
(5 mm) between the lens and the camera.
To attach the lens, proceed as follows:
Remove the rear lens cap and the camera body cap.
Screw the lens carefully into the CS lens mount (
If using a DC auto iris lens, connect the lens cable to the DC auto iris interface (
).
The camera is by default configured for use with DC auto iris lenses.
If using a lens with manual iris control, you have to reconfigure the camera accordingly (see
” on page 40). Video signal-controlled lenses are not supported.