DF4900HD / DF4500HD
www.dallmeier.com
46
11 Interfaces
11.1
Data Display
The data display function provides the embedding of data transferred from external de-
vices/applications (via DaVid Protocol).
The embedded data is displayed in live mode of DaVid Protocol capable devices/applica-
tions. A recording of the embedded data has to be configured separately. For detailed
information refer to the separate documentations.
11.1.1
Filter
The external transferred data can be filtered before embedding.
The filtering (selection) only takes effect on external sent data.
Open the
Data display - Filter
dialogue via
interfaces
>
Data display
>
Filter ...
.
Fig. 11-1
By default, no external transferred data is embedded.
To embed external transferred data, proceed as follows:
Activate the
Display active
checkbox.
Select the relevant data by activating the related checkbox.
Select the
Duration
.
Confirm with
oK
.
The external transferred data is embedded in the current image (frame) present at the mo-
ment when the data is received and keeps embedded for the selected
Duration
(frames).