6.2
Surface Mount Variant
The housing base is mounted with 3 screws (Ø 4 mm) to the ceiling/wall.
You need:
• T20 torx wrench
• Marking tool (e.g. awl)
• 3 mounting screws (Ø 4 mm)
• 3 anchors
• Electric drill
• Screwdriver
Unscrew the 3 housing screws (
) using a T20 torx wrench and remove the
housing.
Mark the drill holes on the ceiling/wall using the 3 pre-drilled mounting holes of the
housing base (
At the marked locations, drill holes fitting for the screws/anchors to be used.
Push anchors suitable for the ceiling/wall material in the drill holes.
Run the required cables suspended from the ceiling/wall through a PG16 cable gland.
Screw the PG16 cable gland in the appropriate thread of the housing base.
Mount the housing base with 3 screws to the ceiling/wall.
Ceiling/Wall
Drill hole
Anchor
Mounting screw (Ø 4 mm)
Thread for
PG16 cable gland
Housing base
Fig. 6-6
Connect the required cables to the connectors of the camera module
Connect the power supply unit to the mains socket.
Connect a CVBS monitor to the video preview output (
).
Adjust the lens direction using the 3-axis mount and set the focal length and focus.
Disconnect the CVBS monitor.
Attach the housing to the housing base and tighten the 3 housing screws (