DS3112
114 of 133
Table 13-4. AC Characteristics—CPU Bus (Multiplexed and Nonmultiplexed)
(V
DD
= 3.3V
±
5%, T
A
= 0
°
C to +70
°
C for DS3112; T
A
= -40
°
C to +85
°
C for DS3112N.)
(See
PARAMETER SYMBOL
MIN
TYP
MAX
UNITS
NOTES
Setup Time for CA[7:0] Valid to
CCS
Active
t1 0 ns
Setup Time for
CCS
Active to
CRD
,
CWR
, or
CDS
Active
t2 0 ns
Delay Time from
CRD
or
CDS
Active
to CD[15:0] Valid
t3
65
ns
Hold Time from
CRD
or
CWR
or
CDS
Inactive to
CCS
Inactive
t4 0 ns
Hold Time from
CCS
or
CRD
or
CDS
Inactive to CD[15:0] Tri-State
t5 5
20
ns
Wait Time from
CWR
or
CDS
Active
to Latch CD[15:0]
t6 65 ns
CD[15:0] Setup Time to
CWR
or
CDS
Inactive
t7 10 ns
CD[15:0] Hold Time from
CWR
or
CDS
Inactive
t8 2 ns
CA[7:0] Hold Time from
CWR
or
CRD
or
CDS
Inactive
t9 5 ns
CRD
,
CWR
, or
CDS
Inactive Time
t10
75
ns
Muxed Address Valid to CALE Falling
t11
10
ns
2
Muxed Address Hold Time
t12
10
ns
2
CALE
Pulse
Width
t13 30 ns 2
Setup Time for CALE High or Muxed
Address Valid to
CCS
Active
t14 0 ns 2
NOTES:
1)
In nonmultiplexed bus applications (
), CALE should be tied high.
2)
In multiplexed bus applications (
), CA[7:0] should be tied to CD[7:0] and the falling edge of CALE
will latch the address.