Dali T9 User Manual Download Page 36

36 

Image  

Spatial 
resolution 

1.12mrad 

0.67mrad 

Super pixel 
function 

768×576 

1280×960 

Display 
method 

Infrared, visible light, picture-in-picture, dual-band 
fusion image (DSIE) 

Digital zoom 

1~4x 

Visible light 
camera 

500 million pixels 

Video output 

HDMI 

Anchor point 
display 

Laser positioning points are displayed on the 
image 

Storage  

Memory 

TF card 

Video 
recording 

Yes, the general video format storage of this 
machine, timing storage can be set, support 
infrared, visible light, fusion mode 

Image 
storage 

Yes, infrared image JPEG format, with infrared 
temperature data; visible light, fusion JPEG format 
storage 

Note 

60-second voice recording, stored with the image, 
optional text annotation 

Measurement  

Temperature 
range 

-20

℃~

+650

℃,

can be extended to 1200

 

Temperature  
accuracy 

±2

 or ±2% of measured value, whichever is 

greater 

Temperature 
measurement 
mode 

Real-time 4 movable points (the hottest and 
coldest points are independent), 3 movable areas 
(the highest temperature, the lowest temperature 
capture, average temperature measurement), line 
temperature measurement, isothermal analysis, 
temperature difference measurement, 
temperature alarm (sound, color) 

Temperature  
correction 

Automatic (short time, long time, custom) / manual 

Atmospheric 
window 
correction 

Corrected according to infrared window 
transmittance 

Atmospheric 
transmittance 
correction 

Automatic, according to the input target distance, 
relative humidity, ambient temperature 

Background 
temperature 
correction 

Automatically correct according to the entered 
temperature 

Emissivity 
correction 

The emissivity is adjustable from 0.01 to 1.0 (in 
increments of 0.01), or the emissivity can be 
corrected through a predefined material emissivity 
meter 

Power system 

Battery 

Rechargeable lithium battery, replaceable 

Battery 
working time 

4 hours  

Battery 
charging time 

Fast charging function (external charger), can be 
charged randomly 

Power 
management 

Automatic sleep, automatic shutdown 

Physical 

characteristic 

Overall size 

W116×D175×H278mm 

Total Weight 

≤1.1kg

including battery

 

Summary of Contents for T9

Page 1: ...T9 T10 Thermal Imaging Camera User manual Copyright 2019 DALI TECHNOLOGY...

Page 2: ...be directly aimed at a strong radiation source such as the sun direct or reflected laser beam etc otherwise it will Permanent damage to the thermal imager Caution The original packaging box must be u...

Page 3: ...7 1 2 Optional configuration 8 2 Introduction 9 2 1 Button function 9 2 2 Interface 11 3 Operation 12 3 1 Battery installation and replacement 12 3 1 1 Battery loading and unloading 12 3 1 2 Battery r...

Page 4: ...ack 25 4 8 Setting 26 4 8 1 Temperature measurement parameter setting 27 4 8 2 Temperature measurement function setting 28 4 8 3 Image setting 31 4 8 4 Storage setting 33 4 8 5 Connection setting 33 4...

Page 5: ...easurement 1 arbitrary line temperature measurement 11 color codes can be selected Infrared and visible light image fusion Isothermal function Temperature measurement setting Fusion of high and low te...

Page 6: ...rtcuts Power saving mode multi language Time date setting reset Upgrade options Optional wide angle lens 0 5x medium focus lens 2x or long focus lens 3x It can extend the temperature measurement at hi...

Page 7: ...etection of the temperature of the slab produced from the furnace etc Fire protection forest fire prevention and potential fire source search spontaneous combustion prevention test of special material...

Page 8: ...r USB data cable HDMI video cable 1 2 Optional configuration 0 5x wide angle lens 2x medium focal lens 3x telephoto lens Portable backpack Non national standard European standard British standard Aust...

Page 9: ...9 2 Introduction 2 1 Button function 1 7 2 4 3 5 6 8...

Page 10: ...ent menu operation or return to the previous menu In the active image mode short press to auto focus 4 Storage key Used to freeze or save the image Press this key once to freeze the image press this k...

Page 11: ...en rotates the focusing ring clockwise to adjust the focus toward the far focus direction rotates the focusing ring counterclockwise to adjust the focus toward the near focus direction 2 2 Interface 1...

Page 12: ...haped elastic area on both sides of the battery cover as shown by the red arrow and pull it outward to remove the battery When inserting the battery the battery is designed with a foolproof structure...

Page 13: ...g storage in order to avoid possible over discharge during storage and affect the battery capacity the battery should be fully charged and stored And charge it at regular intervals The time interval i...

Page 14: ...used batteries in accordance with local government regulations 3 3 Lens loading and unloading Align the red dot of the lens with the red dot in the instrument insert it carefully and rotate it clockwi...

Page 15: ...ding temperature measurement objects see 4 2 Temperature Measurement Mode If you want to perform detailed temperature measurement of the thermal image displayed on the current screen you can store the...

Page 16: ...erature measurement line press and hold the spot on the line you can drag the temperature measurement line as a whole press and hold any point at both ends of the line you can drag one end of the temp...

Page 17: ...temperature measurement object as the reference object please refer to 4 8 2 Temperature measurement function setting Note The thermal imager can only set one reference temperature measurement target...

Page 18: ...u interface and press the return button to exit the menu Icon interface When the secondary menu is an icon interface press the left and right buttons to switch icons press the middle button to confirm...

Page 19: ...value of the temperature measurement object 2 Battery status Display the current battery power status 3 Storage mark indicates that the current image is being saved 4 Recording mark indicates that it...

Page 20: ...easurement object 13 Compass logo indicates the current direction Note There are different functions in different modes and all the signs in the interface may not be displayed in various modes 4 1 2 D...

Page 21: ...ture measurement objects including temperature measurement points temperature measurement areas temperature measurement lines etc Press the middle button or tap the touch screen to pop up the main men...

Page 22: ...e a single temperature measurement object you can directly click the touch screen to select the temperature measurement object and then click the delete icon at the bottom of the screen to delete it 4...

Page 23: ...lide your finger on the touch screen to adjust the upper and lower temperature values of the color code separately or at the same time Click the selected temperature value again to cancel the selectio...

Page 24: ...This function is used to save the video The storage format of the video is MP4 screen recording or DLV only applicable to infrared images Continuing the operation from the previous section when the p...

Page 25: ...Click the playback icon on the touch screen or use the left and right keys to select and then press the middle key to pop up the picture library interface as shown in the figure below Click the corre...

Page 26: ...tch files by pressing the up down left and right buttons and press the middle button to open the playback Activate the icon to edit the file click the check box on the file and click the icon to delet...

Page 27: ...ting After entering the setting menu interface use the buttons or touch screen to operate the menus at all levels which have been described in 3 4 7 menu operation instructions and will not be repeate...

Page 28: ...nsmittance Spread ratio select process according to surface material and then select the corresponding material from the predefined material list you can also select custom value and then scroll up an...

Page 29: ...e temperature measurement target can choose a temperature in point line or area and only one reference temperature measurement target can be set the reference temperature value can be selected by the...

Page 30: ...ions can be set Alarm color setting When the target temperature exceeds the set alarm temperature the area exceeding the alarm temperature will be displayed in the set alarm color The system provides...

Page 31: ...line temperature measurement and regional temperature measurement of the temperature measurement object including the highest temperature the lowest temperature the average temperature and the maximum...

Page 32: ...the icon on the right side of Distance Setting Switch to turn it on or off When it is turned on the fusion distance will be adjusted according to the laser ranging result when it is turned off it sta...

Page 33: ...ideo settings video format MP4 dlv can be selected dlv is only used for infrared images TF card format You can choose to confirm to format the TF card or choose to cancel to return Storage directory s...

Page 34: ...lable devices and select available devices to connect after connecting you can disconnect the current operation 4 8 6 System setting In the system setting menu there are options such as language setti...

Page 35: ...stem Information You can view information such as model number device number software version number MAC address etc Factory mode setting It is used inside the factory and requires a password to enter...

Page 36: ...re independent 3 movable areas the highest temperature the lowest temperature capture average temperature measurement line temperature measurement isothermal analysis temperature difference measuremen...

Page 37: ...tooth module Audio output input Bluetooth headset GPS Yes Electronic compass Yes Set up Date time temperature unit K language LCD backlight IP address 11 Environmental parameter Operating temperature...

Page 38: ...ambient temperature is too low The rechargeable battery is not fully charged Recharge the rechargeable battery The rechargeable battery is completely exhausted and cannot be recharged Replace with a...

Page 39: ...ass Polished plate 20 0 94 Paint White 100 0 92 Natural black 100 0 97 Carbon Smoky 25 0 95 Candle smoke 20 0 95 Graphite rough surface 20 0 98 Paint 16 colors average 100 0 94 Paper white 20 0 93 San...

Page 40: ...ting parameter table Parameter Value Temperature alarm Turn off Alarm temperature 50 0 C Alarm color None Isothermal color Turn off Upper isothermal limit 51 C Lower isothermal limit 49 C Table 4 Syst...