Matrix PS System Installation and Commissioning Guide
|
103
Dali Wireless Proprietary and Confidential | DW-MAN-036 Rev 06
1 0
MAT R I X CO NS O L E P S
I NSTAL L AT I O N
This chapter describes how to:
Rack mount the Matrix Console PS
Connect Ethernet cables to the unit per the IP networking plan
Power on the Matrix Console PS
10.1
Preparing for Installation
Before installing the Matrix Console PS, become familiar with the following installation
workflow, power consumption, and warnings. For FCC compliance and Safety
Information, see the FCC statements at the beginning of this document.
10.1.1
Power Consumption
The Matrix Console PS consumes 50 W. For power consumption details, see
10.1.2
Warnings
This equpment is considered as permanently connected device. A
readily accessible AC disconnect device shall be incorporated
external and close to the equipment.
This equipment is to be installed in a Restricted Access Area.
When installed in a wet, outdoor area, turn power off prior to
unit modifications.