RATOON XL
Page 18
Disconnect from the tractor, as described in "Connection and disconnec-
tion". Activate the hydraulic handle until the pressure on the manometer
shows 150 bar.
Important!: The NSH system pressure must NOT exceed 150 bar. If it does, the ac-
cumulator will fill up with too much oil, reducing its ability to take oil from a cylin-
der. This will cause the entire system to lose power to some degree, and pressure
in the system will rise. This can increase the risk of damage to the system.
Check all the accumulators on the machine at least once a year for leaks and to
ensure that the precharge pressure is set correctly. Contact an authorized DALBO
dealer for more information.