– 17 –
Refer to the table below for a list of all available test patterns and their descriptions.
Test Pattern
Description
Module Locator
Displays an alternating pattern showing the row and then the column
of each module
Module ID
Displays a pattern that numbers each display module
Module ID 48x48
Displays a module ID pattern rendered at 48x48 for non-square/non-
matrix modules
Module ID 32x32
Displays a module ID pattern rendered at 32x32 for non-square/non-
matrix modules
Module ID 16x16
Displays a module ID pattern rendered at 16x16 for non-square/non-
matrix modules
Color Bars
Displays a pattern similar to SMPTE color bars
Diagonal Pattern
Displays scrolling red, green, and blue diagonal lines from left to right
across the display
All On
Displays red, green, blue, and white on the entire display
All On Red
Displays red on every pixel of the display
All On Green
Displays green on every pixel of the display
All On Blue
Displays blue on every pixel of the display
All On White
Displays white on every pixel of the display
All Off
Displays black on the entire display as the LEDs are turned off
Calibration Corners
Displays a pattern of dots on the corners of every module to aid in field
calibration
Calibration Half On
Displays a RGB sequence with reduced brightness for field calibration
Stored Content
Select
Stored Content
from the drop-down menu to use locally stored image files as
the input source. Refer to
for supported image file types
and instructions for uploading content. Stored content must be available for the
Stored
Content
display mode to function. Refer to
.
The
Minimum Hold Time
sets how long the stored content is displayed.
Figure 35:
Input - Stored Content Display Mode