– 5 –
7-Segment Error Codes
A 7-segment indicator appears on the following components;
refer to
. The 7-segment indicator provides codes to
indicate any present errors and their cause. When an error
occurs, the 7-segment will flash the error code. If multiple errors
are present, the 7-segment will flash the errors individually in
succession. If no errors are present, the 7-segment will show a
continuously looping figure-8.
Modules
7-Segment Error Code
Error
Cause
1
Communications Lost
No CAN packets received for
10 seconds
2
Failed Pixel
Refer to the
table
.
3
Power Failure
Input Voltage has dropped
below 20 VDC
8 (Solid)
Lost Packet
Diagnostic packet, FIFO full
8 (Looping)
No Error
VCB
7- Segment Error Code
Error
Cause
1
Communications Lost
No fiber packets for 15
seconds
3
Power Failure
Board voltages below limit:
V-ln, 1 and 2 < 20 VDC
9 V < 8.52 VDC
3.3 V < 3 VDC
2.5 V < 2.37 VDC
1.2 V < 1.1 VDC
8 (Looping)
No error
Isolation Board
7-Segment Error Code
Error
Cause
1
Communications Lost
No CAN packets for 10
seconds
2
Input power failure
V-In < 21 VDC
5
Output power failure
V-In < 21 VDC (with V-ln OK)
8 (Looping)
No Error
Figure 6:
7-Segment