Control System Overview
11
7 Control System Overview
The GT6x Large Matrix series control components are enclosed in the display.
Fully Embedded Control System
The control enclosure for
large matrix GT6x series
displays is located in the
bottom-left corner of the
display. There are two
control configurations
shown. The table below
describes each control
system. Refer to
and
component descriptions.
Component
Function
Number
Thermostat
Measures the temperatures inside the ISP enclosure and turns on the fan
or the heater as needed.
1
Heater
Since ISP equipment is affected by lower temperatures, a heater
prevents the ISP enclosure from going below a functional range.
2
Fan
High heat can damage some electronics, the fan cools the ISP
enclosure to keep the equipment in a safe functional range.
3
POE
Ethernet
Switch
Connects network devices and provides webcam power.
4
DMP-8000
Converts content data from the content management server into a
format recognized by the VIP and sends it out to the VIP-5160.
5
DMP-5060
• Converts data to a format recognized by the display and sends
the signal to the ProLink Routers (PLRs) in the display. It also gathers
diagnostic data from the display and sends it to IDM.
• Converts content data from the content management server.
6
VIP-5160
Converts DMP-8000 data to a format recognized by the display and
sends the signal to the ProLink Routers (PLRs) in the display. The VIP-5160
also gather diagnostic data from the display and sends it to IDM.
7
Open the ISP Box
To access ISP box components, complete the
following steps:
1�
Access the ISP box by removing modules in
the lower-left corner of the display
2�
Using a Phillips-head screwdriver, loosen the
four screws and lift the door from keyed slots,
3�
After performing service or completing
connections, replace the display door.
Figure 13:
DMP-5060
1
2
3
4
5
6
Figure 14:
ISP Enclosure
Screw Locations
Figure 15:
Control Equipment Door