Electrical Installation
3-4
openings in the top of the bottom section and the bottom of the top section
to plug the jack from the power termination panel into the plug coming
from the Z-filter as shown in
2.
Connect the ground strap from the ground lug in the bottom row of the top
section to the ground lug on the top row of the bottom section as shown in
3.
The light sensor is located at the top row of the top section. Connect the
provided cable from the light sensor to the controller located in the bottom
row of the bottom section. Refer to
and the appropriate
Schematic Drawings
located in
Appendix A
.
4.
The ribbon cables run from the top section to the bottom section. They plug
into quick connects which are installed in the display, and route down to the
controller located in the bottom row of the bottom section. Refer to the
appropriate
Schematic Drawings
and
for ribbon cable details.
3.4 Conduit
Daktronics
does not
include the conduit. A separate conduit must be used to route:
•
Power
•
Signal IN wires to the signal termination enclosure when applicable
•
Signal OUT wires (if not using the provided interconnect cable)
Knockouts are on the rear of the display for power and signal. Some of the
monochrome displays will have a 2x4 junction box (J-box) for termination of power.
Unthreaded knockout holes are provided in the signal enclosures used with the
display. If necessary, there are knockout/drill holes in the display when not using the
provided enclosures.
For displays with more than one face, signal wiring between displays is normally
done using a quick connect interconnect cable (length 6 feet). If the displays are too
far apart for the interconnect cable, two primary displays will be used. The
interconnect wiring is included in the manual for your communication type.
3.5 Preparing for Power/Signal Connection
Reference Drawing:
Layout Drawing.......................................................................
Appendix A
Note the following when connecting power to the display:
1.
Enclosures are provided with the display for termination of signal (
Section
3.6
shows the internal wiring for the power, and the manual for your
communication type shows an alternate termination method for the signal).
2.
Route power to the display through a fused disconnect switch capable of
opening all ungrounded power conductors. Install this disconnect within the
line of sight of any personnel performing maintenance on the display. If the
disconnect is located out-of-sight of the display, it must be capable of being
locked in the open position.
Summary of Contents for Galaxy AF-3400 Series
Page 2: ......
Page 4: ......
Page 6: ......
Page 10: ......
Page 24: ......
Page 40: ...Figure 27 Control Corner Component Locations Maintenance and Troubleshooting 4 6...
Page 54: ......
Page 55: ......
Page 56: ......
Page 57: ......
Page 58: ......
Page 59: ......
Page 60: ......
Page 61: ......
Page 62: ......
Page 63: ......
Page 64: ......
Page 65: ......
Page 66: ......
Page 67: ......
Page 68: ......
Page 69: ......
Page 70: ......
Page 71: ......
Page 72: ......
Page 73: ......
Page 74: ......
Page 75: ......
Page 76: ......
Page 77: ......
Page 78: ......
Page 79: ......
Page 80: ......
Page 81: ......
Page 82: ......
Page 83: ......
Page 84: ......
Page 85: ...Appendix B Optional Temp Sensors B 1 Appendix B Optional Temperature Sensor...
Page 92: ......
Page 93: ......