Daktronics FLR3-400 Installation Quick Manual Download Page 4

DD2239290 Rev 03

6 August 2014

PO Box 5128 201 Daktronics Drive, Brookings, SD 57006-5128

tel: 800-325-8766 fax: 605-697-4700

www.daktronics.com

AH

GEN III FUELIGHT

RISER DIAGRAM; FLR3-400

LSOPER

12 SEP 12

P1611

R 01 A

NONE

LSOPER

1113268

01

1 OF 1

3

2

1

LINE

SYNC

ADDR

CONFIG

TEST

4

LL-2855 REV00

FUELIGHT DISPLAY

MD

MAIN DISCONNECT

OVERALL SIGN STRUCTURE

SEE NOTE 4 A&B

FUELIGHT DISPLAY

1. POWER FEEDER SIZED AS NEEDED, BY CUSTOMER. ALL WIRING TO MEET OR EXCEED LOCAL AND NATIONAL ELECTRICAL CODES.

2. 2 KNOCKOUTS PROVIDED FOR 3/4" CONDUIT FITTING ON REAR OF DISPLAY FOR POWER AND SIGNAL ENTRANCE.

3. REFER TO MANUAL FOR LINE-TO-LINE WIRING BETWEEN DISPLAYS.

4A. INSTALL OPTIONAL QUICK CONNECT PANEL IN THE SIGN STRUCTURE NO MORE THAN 8 FEET FROM THE DISPLAY DRIVER.  DRILL 7/8" HOLE IN SIGN STRUCTURE TO PASS CONNECTIONS THROUGH.  USE INCLUDED BUSHINGS WHERE APPLICABLE.

4B. RUN OPTIONAL QUICK CONNECT CABLE PROVIDED WITH DIRECT ACCESS PORT THROUGH 3/4" CONDUIT TO THE SIGN STRUCTURE. SEE JBX WIRING TABLES FOR WIRE TERMINATIONS.

4C. OPTIONAL DIRECT ACCESS PORT KIT NOT INCLUDED IN FLR3-400 KIT.

4D. OPTIONAL WIRED CONTROLLER NOT INCLUDED IN FLR3-100 KIT OR DIRECT ACCESS PORT KIT.

4E.  JBX2 CONNECTION IS NOT TO BE USED WITH A LAPTOP.

5. SEE DWG-1092852 FOR OPTIONAL DIRECT WIRED COMM OPTION AND WIRING DIAGRAM.

6. ADDITIONAL PYLONS REQUIRE ADDITIONAL FLR3-400 KITS.

JBX2

400FT MAX

COMPONENT IDENTIFICATION TABLE

COMPONENT

DESCRIPTION

PROVIDED BY

INSTALLED BY

DRIVER

FUELIGHT DRIVER

DAKTRONICS

FACTORY

MD

MAIN DISCONNECT

CUSTOMER

CUSTOMER

KEYFOB REMOTE

KEYFOB REMOTE

DAKTRONICS

CUSTOMER

REC

KEYFOB REMOTE RECEIVER

DAKTRONICS

CUSTOMER

JBX2

OPTIONAL JBOX, DIRECT ACCESS PORT

DAKTRONICS

CUSTOMER

CTRL

OPTIONAL WIRED DM-100 PRICE/T&T CONTROLLER

DAKTRONICS

CUSTOMER

ANT

KEYFOB REMOTE RECEIVER ANTENNA, FLR3-400

DAKTRONICS

CUSTOMER

CABLE IDENTIFICATION TABLE

ID TAG

DESCRIPTION

PROVIDED BY

INSTALLED BY

A

OPTIONAL QUICK CONNECT PNL MNT TO 6 POS MINI MNL, 8FT

DAKTRONICS

CUSTOMER

B

HARN; 6 PIN MINI MNL TO 6 PIN MINI MNL, 5FT

DAKTRONICS

CUSTOMER

C

CABLE:ANTENNA:RP-SMA FEM BULKHEAD TO RP-SMA MAL,12

DAKTRONICS

CUSTOMER

D

POWER FEEDER SEE NOTE "1"

CUSTOMER

CUSTOMER

E

HARN; 6 POS QUICK CONNECT TO WHIP, 50FT (NOT INCLUDED)

DAKTRONICS

CUSTOMER

F

CABLE; RS232 DB9 MALE TO DB9 FEMALE, 10FT

DAKTRONICS

CUSTOMER

G

CABLE; LINE TO LINE; 4 POS MINI MNL,  15 FT

DAKTRONICS

CUSTOMER

NOTES:

DRIVER

D

A

B

DRIVER

C

REC

 CTRL (SEE NOTE 4D)

F

E

DIRECT ACCESS PORT

KIT

(NOT INCLUDED)

SEE NOTE 4C

KEYFOB REMOTE

(INCLUDED)

G

ANT

JBX2 WIRING TABLE CABLE E

BLK

WHT

TB3-2

TB3-3

TB3-4

GRN

TB3-1

RED

01

20 SEP 2013

JJL

ADDED JBX WIRING TABLE

Summary of Contents for FLR3-400

Page 1: ...ounting studs using the two provided nuts 5 Place the threaded end of the antenna cable through the antenna hole 6 Place the flat washer over the threaded end of the antenna cable Refer to Figure 2 7 Thread the provided nut on to the threaded end of the antenna cable and tighten using an 11 32 wrench 8 Thread the female end of the antenna on to the threaded end of the antenna cable and turn the an...

Page 2: ...booting up or within 5 minutes press and hold Line one Plus and Minus keys until the decimal flashes 3 times Refer to Figure 4 3 Once the decimal point flashes 3 times release the buttons Setting the Display Line Numbers Follow these steps to map the line number for each display It is important that each display is set for the correct line number for it to show the correct price 1 Make sure the di...

Page 3: ... Press the Plus or Minus keys to scroll through the different configuration options Note For Domestic displays with a 9 10s digit the number 3 needs to show in the first column for the desired format For International displays make sure the number 4 shows in the first column for the desired format International displays offer two configuration options tails and 9 and no tails and 9 as shown in Fig...

Page 4: ...S NOT TO BE USED WITH A LAPTOP 5 SEE DWG 1092852 FOR OPTIONAL DIRECT WIRED COMM OPTION AND WIRING DIAGRAM 6 ADDITIONAL PYLONS REQUIRE ADDITIONAL FLR3 400 KITS JBX2 400FT MAX COMPONENT IDENTIFICATION TABLE COMPONENT DESCRIPTION PROVIDED BY INSTALLED BY DRIVER FUELIGHT DRIVER DAKTRONICS FACTORY MD MAIN DISCONNECT CUSTOMER CUSTOMER KEYFOB REMOTE KEYFOB REMOTE DAKTRONICS CUSTOMER REC KEYFOB REMOTE REC...

Reviews: