First-Time Power Up
22
10 First-Time Power Up
A laptop is required to communicate with the display. In the ISP enclosure, connect the
red Ethernet cable with the Connect to Laptop tag to an Ethernet port on the laptop.
First-Time Power Up
1�
Loosen the 3/4 turn latches that secure the ISP
.
2�
Open the ISP enclosure cover, if desired, lift
and remove the ISP enclosure cover off the
hinges. Hinge locations shown in
.
3�
Install the Modem according to the ISP
schematic. Ensure the modem has power and
is connected to the network switch. Ensure the
webcam is connected to the POE network
switch.
4�
For displays sharing the Internet connection,
connect a Cat5 cable from port 8 on the
network switch of the primary display to port 8 of the network switch on the
secondary display.
5�
Turn on site power at the main breaker at the structure base.
6�
Verify the status lights on the surge suppressor are on.
7�
Check the LED indicators on the equipment in the ISP enclosure to ensure they are
on.
8�
Ensure the DMP-8065 LED indicators LEDs are on.
The power light runs steadily, the DMP and VIP run
indicators flash.
9�
Connect a laptop to the red crossover cable in the
ISP enclosure.
10�
Call Daktronics help desk at 1-877-DAK-HELP to verify
connectivity to the display, perform a diagnostics
check, activate the SmartLink
TM
, and perform several
display setting checks. The help desk technician will
ask for the SmartLink
TM
ICCID or MEID number. This
number is located on the bottom of the SmartLink
TM
or on the mezzanine card in the SmartLink
TM
. Refer to
.
11�
After the help desk verifies the diagnostics is clean
and performs their tasks, disconnect the laptop from
the cross-over cable and reinstall the ISP enclosure
cover.
3
/
4
-Turn
Latches
Hinges
Figure 37:
ISP Box Door Removal
ICCID
Figure 38:
ICCID Number on
Mezzanine Card