background image

 

 

 

 

DM(AG)

WH7

 

User

 

Manual

 

Rev:

 

10/07/20

                              

              

Page

 

4

 

of

 

8

      

Author:

 

CNR

 

 

 

B.

    

Hardwire

 

Power

 

Adapter

  

1.

     

If

 

you

 

would

 

like

 

to

 

hardwire

 

your

 

power

 

supply,

 

utilize

 

the

 

instructions

 

included

 

in

 

the

 

packaging.

 

2.

    

Dakota

 

Micro

 

hardwire

 

power

 

adapters

 

have

 

a

 

maximum

 

circuit

 

capability

 

of

 

5

 

amp.

 

 

C.

    

Fuses

 

1.

   

There

 

is

 

a

 

small

 

in

line

 

glass

 

fuse

 

located

 

on

 

the

 

red

 

and

 

black

 

power

 

wire

 

(3

 

above).

 

When

 

replacing

 

this

 

fuse,

 

use

 

a

 

MAX

 

2amp

 

glass

 

fuse.

 

2.

   

There

 

is

 

a

 

small

 

glass

 

fuse

 

located

 

on

 

the

 

inside

 

tip

 

of

 

the

 

12v

 

portion

 

of

 

the

 

power

 

adapter

 

(PN:

 

DMAC

12v).

 

When

 

replacing

 

this

 

fuse,

 

use

 

a

 

MAX

 

2amp

 

glass

 

fuse

 

 
 

VII.

 

EVENT

 

TRIGGER

 

WIRE

 

OPERATIONS

 

A.

   

Event

 

Trigger

 

Wire

 

Color

 

Guide

 

1.

 

Camera

 

1

 

 

Green

 

2.

 

Camera

 

2

 

 

Purple

 

3.

 

Camera

 

3

 

 

Gray

 

4.

 

Camera

 

4

 

 

White

 

 

B.

   

Event

 

Trigger

 

Wires

 

Explained

 

 

Event

 

trigger

 

wires

 

can

 

be

 

attached

 

to

 

any

 

12v

 

positive

 

event.

  

This

 

will

 

cause

 

the

 

monitor

 

to

 

change

 

to

 

that

 

camera,

 

regardless

 

of

 

the

 

state

 

of

 

the

 

monitor

 

(i.e.

 

ON/OFF

 

or

 

channel

 

selection).

 

The

 

most

 

recent

 

event

 

will

 

be

 

the

 

primary

 

display.

  

Example

:

 

if

 

two

 

(2)

 

video

 

channels

 

(AV1

 

&

 

AV2)

 

are

 

attached

 

to

 

an

 

event

 

output,

 

the

 

event

 

that

 

happens

 

last

 

will

 

change

 

the

 

monitor

 

to

 

its

 

respective

 

camera

 

view.

  

 

The

 

wires

 

can

 

be

 

attached

 

to

 

any

 

positive

 

output

 

10.5v

 

to

 

16.9v

 

switch

 

or

 

supply

 

to

 

cause

 

the

 

monitor

 

to

 

switch

 

the

 

unit

 

to

 

its

 

respective

 

camera

 

channel

 

automatically.

 

Example:

 

if

 

you

 

were

 

to

 

attach

 

the

 

AV1

 

wire

 

to

 

a

 

positive

 

output

 

from

 

an

 

unloading

 

auger

 

on

 

a

 

combine,

 

the

 

monitor

 

would

 

switch

 

from

 

channel

 

2,

 

3,

 

or

 

4

 

to

 

channel

 

1

 

when

 

the

 

auger

 

is

 

extended.

 

The

 

event

 

circuit

 

should

 

be

 

neutral

 

in

 

its

 

normal

 

state

 

and

 

change

 

to

 

HIGH

 

(+12v)

 

when

 

the

 

events

 

are

 

active.

 

 

 

VIII.

 

REMOTE

 

&

 

MONITOR

 

OPERATION

 

 

A.

 

Monitor

 

Operations

 

 

Front

   

 

Summary of Contents for DM-WH7

Page 1: ...9001 www dakotamicro com Thank you for purchasing our Dakota Micro Inc products Table of Contents I Included Monitor Kit Components 2 II Standard Features 2 III Important Information About AHD Analog...

Page 2: ...ameras for use as a backup camera 2 Year Warranty 16 9 aspect ratio 4 camera inputs Event triggers for each camera allow for triggered events to bring your camera to full view I E putting the vehicle...

Page 3: ...normal operation of equipment WARNING Dakota Micro Inc is not responsible for any damages caused to your monitor or yourself due to the improper installation or use of a suction cup monitor mount whet...

Page 4: ...res Explained Event trigger wires can be attached to any 12v positive event This will cause the monitor to change to that camera regardless of the state of the monitor i e ON OFF or channel selection...

Page 5: ...the and key on the monitor or the right and left arrow keys on the remote to change the value of the highlighted item 5 Use the and key to move up and down through the individual menu selections Press...

Page 6: ...ighting conditions LCD FLIP Allows you to rotate or reverse the image LCD POWER SAVE Set a time the monitor will be placed in power saving mode LANGUAGE LANGUAGE Allows user to select language English...

Page 7: ...NS Screen Size 16 9 Digital Panel Overall Size 7in 4 84 H x7 04 W x1 14 D in 123 H x179 W x29 D mm Weight 396g avg 7in 547g avg 9in Power Input DC 10 32v Color System NTSC PAL auto switch Operating Te...

Page 8: ...oper voltage or other misuse abnormal service or handling or which has been altered or modified in design or construction In order to enforce the rights under this limited warranty the purchaser shoul...

Page 9: ...e increased Camera Warnings NEVER RELY ON YOUR DAKOTA MICRO CAMERA AS A SAFETY FEATURE It is up to your discretion to keep your road travel and other operations safe Your Dakota Micro camera will prov...

Page 10: ...ly to any issues connected with appearance that have no relation to the performance of the Product nor to any Product the exterior of which has been damaged or defaced which has been subjected to impr...

Reviews: