Dakota Digital UTV-1200 Manual Download Page 3

 

 

page 3 

 

MAN#650244:A 

SPEED   

 

 

Speed gauge menu 

 

UNIT 

 

 

 

Select unit for speed  

 

 

 

 

 

 

 

Toggle between MPH and KPH (select unit to use for calibration) 

 

AUTO 

 

 

 

Auto calibrate speed to a marked mile or kilometer 

 

 

 

 

 

 

 

Pulls up all values 



 on speed and speed pulses in odometer 

 

 

 

 

 

 

 

Press Right switch to finish cal and save value 

 

ADJUST  

 

 

Adjust speed cal while driving 

 

 

ADJUST 

 

 

 

Each press of left switch toggles direction of adjustment, right switch to save and exit 

 

SRV MI 

(

SRV KM

 

Sets value of service odometer set when service odometer is reset 

 

 

  OFF 

(

  OFF

)

     

Turns off the count down service odometer (default) 

 

 

  500 

(

  800

)

     

Sets service to 500 mi or 800 km when resetting service odometer. 

 

 

   …. 

 

 

 

Service point can be set in 500 mi (800km) increments. 

 

 

 7500 

(

12000

)

     

Sets service to 7500 mi or 12000 km when resetting service odometer. 

 

MAIN 

 

 

 

Returns to info menu 

 

TACH 

 

 

 

Tachometer gauge menu 

 

update  

 

 

Sets update rate for tachometer readout screen 

 

 

SLOW

 

 

 

tach updates at slowest rate (default) 

 

 

MEDIUM 

 

 

FAST

 

 

 

fastest update on tach 

 

WARN 

 

 

 

Sets RPM warning point (default 5500 RPM) 

 

 

W 2250  

   

Minimum warning point of 2250 RPM 

 

 

….   

 

 

 

Warning point can be set in 250 RPM increments 

 

 

W 9750  

   

Maximum warning point of 9750 RPM 

 

SRV HR  

 

 

Sets service hour value used when resetting count down service hour meter 

 

 

OFF  

 

   

Service hour meter disabled (default) 

 

 

10   

 

   

Minimum service hour set point 

 

 

…   

 

 

 

Service hour reset point can be set in 10 hr increments 

 

 

310  

 

   

Maximum service hour set point 

 

MAIN 

 

 

 

Returns to info menu 

 

GAUGES  

 

 

Gauge option menu 

 

VLT HI  

 

 

Set high voltage warning point (default 15.4V) 

 

VLT LO  

 

 

Set low voltage warning point (default 11.1 V) 

 

OIL LO  

 

 

Set low oil pressure warning point (default 9 PSI) 

 

WTR HI  

 

 

Set high water temp warning point and set temperature unit (default 251F) 

 

 

DEG F 

(

DEG C

 

 

Select temp unit, press left switch to change, right switch to save 

 

 

WTR HI  

   

Select high warning, left switch to change, right switch to save 

 

MAIN 

 

 

 

Returns to info menu  

 

OPTION  

 

 

Option menu 

 

DIM LV  

 

 

Adjust dimming point on gauge 

 

 

OFF  

 

   

Dimming function is off 

 

 

LVL 1   

   

Gauge will dim when light on gauge face is very low (default) 

 

 

…   

 

 

 

7 selectable dimming levels 

 

 

LVL 7   

   

Gauge will dim early when more light is on gauge face 

 

DM OUT  

 

 

Enables/disables dim output for other gauges 

 

 

ON   

 

   

Dim output will be high when gauge is dimming 

 

 

OFF  

 

   

Dim output will be disabled (default) 

 

WN OUT  

 

 

Selects which gauges provide a warn out signal on warn out wire (default all on) 

 

 

WN OUT 

 

 

 

Gauges that provide signal out are lit up, left switch to change, right switch to save 

 

 

NO WRN 

 

 

 

Warn output wire is disabled 

 

CLOCK±  

 

 

Adjust clock speed for accuracy 

 

 

-7 SEC  

   

Subtract 7 seconds from clock every 24 hrs 

 

 

… 

 

 

 0 SEC  

   

No adjustment to factory clock speed (default) 

 

 

… 

 

 

+7 SEC  

   

Add seven seconds to clock every 24 hrs 

 

St odo

   

 

 

Allows presetting of odometer value on initial install (not available after 10 miles / 16km) 

 

Set hr

   

 

 

Allows presetting of hour meter value on initial install (not available after 1.0 hrs) 

 

MAIN 

 

 

 

Returns to info menu 

 

DONE 

 

 

 

Leaves setup menu if selected 

Reviews: