Calibration 

 

Adjust while driving:

  To increase the speedometer reading, press and hold the + push 

button switch.  To decrease the speedometer reading, press and hold the - push button switch.  The 
calibration will only change when the vehicle is in motion and a speed signal is present. 

 

Preset or adjust while parked:

  The calibration value can be set from 0.250 

– 4.00. Values 

below 1.00 will display as three digits with no decimal point. (0.250 = 250) 
 
1.  Begin with the key off.   
2.  Press and hold the SET switch while turning the key on.  The display will show the current version 

code. 

3.  Release the SET switch.  The 

display will show “



”. 

4. 

Press and release the INC switch until “



” is displayed, then press and release the SET switch. 

5.  The display will show the ones digit of the currently stored calibration value.  Press and release 

the INC switch to set this from 0.-4. for your desired calibration value. 

6.  Once finished, press the SET switch to move to the tenths digit.  Press and release the INC 

switch until your desired value is shown. 

7.  Press the SET switch to move to the hundredths digit.  Press and release the INC switch until 

your desired value is shown. 

8.  Press the SET switch to save the hundredths digit.  If the value is 1.00 or higher the calibration 

value will be saved.  The calibration set is done. 

9.  If the value is 0.99 or lower the thousands digit will now be set.  Press and release the INC switch 

until the desired value is shown.  Press the SET switch to save and finish. 

10. The display should now show the next me

nu option, “



”.  Turn the key off 

Summary of Contents for SGI-5 E

Page 1: ...ter 5 Convert a 16000ppm signal from a VDO Hall Effect signal generator to an 8000ppm 4000ppm or 2000ppm to run a cruise control or fuel injection computer 6 Convert a 4000ppm signal from an OEM trans...

Page 2: ...in low speed out OUT3 4 of OUT1 OUT5 of OUT1 1 Begin with the key off 2 Press and hold the SET switch while turning the key on The display will show the current version code 3 Release the SET switch T...

Page 3: ...l is displayed then press and release the SET switch 5 The display will show the ones digit of the currently stored calibration value Press and release the INC switch to set this from 0 4 for your des...

Page 4: ...or buffer side will go to the OUT1 terminal If the speedometer does not operate correctly after installation of the SGI 5 you may need to switch to OUT2 instead of OUT1 Connect the POWER terminal to...

Page 5: ...WER terminal to a 12 volt accessory wire and connect the GROUND terminal to a good ground location You can determine how far the speedometer is off by having it checked with radar a GPS unit or follow...

Page 6: ...ome typical examples OUT3 8000ppm AC most aftermarket speedometers and cruise controls OUT4 4000ppm oc most TPI computers and some OEM cruise controls OUT5 2000ppm oc most TBI computers and some OEM c...

Page 7: ...2000ppm oc most TBI computers and some OEM cruise controls APPLICATION 5 Convert a 16000ppm signal from a Hall Effect signal generator to 8000ppm 4000ppm or 2000ppm to run a cruise control or fuel inj...

Page 8: ...wire sensors can be recalibrated with this unit Two wire sensors will typically have one wire as a ground and the other as the signal Three wire sensors will have an additional power wire You must fir...

Page 9: ...switch while turning the key on The display will show the current version code 3 Release the SET switch The display will show 4 Press and release the INC switch until is shown 5 Press and release the...

Page 10: ...nical support line 605 332 6513 to request a Return Merchandise Authorization number Package the product in a good quality box along with plenty of packing material Ship the product by UPS or insured...

Reviews: