PAC-2700 

ELECTRIC COOLING FAN CONTOLLER 

G

ND

SENDE

R

S

W

1

IG

N

IT

IO

N

F

A

L

O

W

+

12v

A/

C

F

AN H

IG

H

S

W

2

CUSTOM

ADJUSTMENT

PAC-2700

FAN CONTROLLER

FAN2

Fa

PW

+

1

2

V

LOW

FAN1

FAN

HIGH

+12V

Not used in

sender only
application

+12V with key ON

A/C clutch cycle switch

Fused battery 12V

Choose
option
below

SENDER

GAUGE

single fan

two separate fans

dual speed fan

Fan
High

Fan
High

Fan
Low

Fan
Low

+12V

NOT

CONNECTED

FAN

Fan
Low

Fan
High

(+12v trigger)

+12V

Fa

PW

+

1

2

V

Fan 

PWR
+12V

 

 

IMPORTANT NOTE:

  

The +12V for the 
controller should NOT 
be taken from the same 
circuit as the Fan Power 
12V as this can cause 
the fan to cycle on and 
off.  

Summary of Contents for PAC-2700

Page 1: ... application 12V with key ON A C clutch cycle switch Fused battery 12V Choose option below SENDER GAUGE single fan two separate fans dual speed fan Fan High Fan High Fan Low Fan Low 12V NOT CONNECTED FAN Fan Low Fan High 12v trigger 12V Fan PWR 12V Fan PWR 12V IMPORTANT NOTE The 12V for the controller should NOT be taken from the same circuit as the Fan Power 12V as this can cause the fan to cycle...

Page 2: ...er full sweep use of a dedicated Dakota Digital sender is required If a gauge is not used ONLY a Dakota Digital 300ºF sender should be used Other senders may not give a correct reading to the control unit Custom gauge calibration requires numerical marks stock C NORMAL H type gauges cannot be accurately calibrated to Required components for installation The PAC 2700 is shipped with necessary compo...

Page 3: ...45 seconds after key is turned off If fan was running at key off it will continue to run for 1 minute after key is turned off If fan was running at key off it will continue to run for 2 minutes after key is turned off If fan was running at key off it will continue to run for 3 minutes after key is turned off If fan was running at key off it will continue to run for 5 minutes after key is turned of...

Page 4: ...will return the device to the original factory presets and clear custom calibration settings NOTE Calibration data for the custom gauge setup will be lost when reset to factory presets 1 Turn key off 2 Press and hold SW1 and SW2 and turn key on 3 Display will read for reset 4 Display will flash to indicate unit is reset Factory reset values are listed at the beginning of the setup portion of this ...

Page 5: ... Shorten fan delay time to prevent excessive battery drain Fan turns on late or not at all Unit has no power Broken shorted wire to sender Wrong gauge is selected gauge setup Wrong sender used for no gauge setup On temperature in setup is too high Fan not connected properly Alternator overcharging Analog gauge applications only With key on hold SW1 if the display doesn t show a temperature after a...

Page 6: ...ame and address street address preferred and a telephone number where you can be reached during the day Any returns for warranty work must include a copy of the dated sales receipt from your place of purchase Send no money We will bill you after repair Dakota Digital 24 Month Warranty DAKOTA DIGITAL warrants to the ORIGINAL PURCHASER of this product that should it under normal use and condition be...