Dakota Digital PAC-2000 Quick Start Manual Download Page 5

 

 

 

MAN# 650113D

 

TROUBLESHOOTING 

PROBLEM 

CAUSE 

SOLUTION 

Display reads “Er0” 
(lost memory) 

Setup memory lost, unit needs to be 
recalibrated. 

Go through setup procedure, (see setup in this manual) 

Display reads “Er1” 
(shorted sender) 

Wrong gauge selected 
 
 
Gauge disconnected from sender. 
(gauge option only) 
 
Sender is shorted 
 
Unit not connected to sender 

Select proper gauge in setup or use custom cal if 
needed. 
 
Reconnect gauge to sender. 
 
Check sender wire for short to ground. Look for pinched 
sender wire or bare connection touching ground 
 
Connect send terminal on unit to sender circuit 

Display reads “Er2” 
(open sender) 

Wrong gauge selected 
 
 
Sender not connected. 
 
Unit not connected to sender. 

Use setup to select proper gauge, or use custom cal if 
needed. 
 
Reconnect wire to sender 
 
Connect send terminal on unit to sender circuit.  

Display reads “Er3” 

Setup data is out of valid range. 

Go through setup again, custom cal may be incorrect if 
just set. 

Display reads “bAt” 
when attempting to go 
into setup 

+12v terminal does not have 
constant power. 

C12v terminal to fused battery connection. This 
terminal should have constant power at all times. 

Display alternates 
between “Lo” and “bAt” 

Battery voltage dropped too low 
during key off extended fan on time. 

Ensure battery is fully charged. Check and replace weak 
battery. Shorten fan delay time to prevent excessive 
battery drain. 

Fan turns on late, or 
not at all.  

Unit has no power 
 
 
 
Broken/shorted wire to sender 
 
Wrong gauge is selected. 
(gauge setup) 

 

Wrong sender used  
(for no gauge setup) 
 
 
On temperature in setup is too high 
 
 
Fan not connected properly 
 
 
Alternator overcharging 
(Analog gauge applications only) 
 

With key on, hold SW1, if the display doesn’t show a 
temperature after a few seconds, check Battery and 
ground connections. 
 
Check wire to sender for breaks or shorts and repair. 
 
Hold SW1, if temperature read is lower than expected or 
doesn’t match gauge, redo setup. 
 
For sender only applications ONLY a Dakota Digital 
300°F sender can be used. Other senders may not give 
a correct temperature reading. 
 
Hold SW1, if temperature read is above the desired on 
temperature, and fan is not running, redo setup. 
 
Remove fan output from unit and short wire to ground. If 
fan does not run, check relay and fan connections. 
 
Use a voltmeter to measure the voltage at the battery 
while the engine is running. If this voltage is above 15v 
the unit may turn the fan on later than expected. Either 
correct overcharging problem or set on temp lower to 
compensate. 

Fan runs constantly 

Controller has an error 
 
Fan off temp too low 
 
Broken/shorted wire to sender 
 
Wrong gauge is selected 

Check display for error message 
 
Increase off temp in setup 
 
Check wire to sender for breaks or shorts and repair. 
 
Select appropriate gauge in setup, or custom calibrate if 
your gauge is not supported. 

Summary of Contents for PAC-2000

Page 1: ...CONNECTED NOT CONNECTED FAN2 12V NOT CONNECTED NOT CONNECTED LOW FAN1 FAN HIGH 12V Not used in sender only application 12 V with key ON A C clutch cycle switch Fused battery 12V Choose option below SENDER GAUGE single fan two separate fans dual speed fan REV D Fan High Fan High Fan Low Fan Low 12V NOT CONNECTED FAN NOT CONNECTED Fan Low Fan High 12v trigger ...

Page 2: ...nteed to properly control the fan possibly leading to overheating and engine damage If a gauge is not used ONLY a Dakota Digital 300 F sender should be used Other senders may not give a correct reading to control unit Required components for installation The PAC 2000 is shipped with necessary components for use with a single fan on a gauged system These parts include 1 PAC 2000 module 1 RLY 1 rela...

Page 3: ...o run for 45 seconds after key is turned off If fan was running at key off it will continue to run for 1 minute after key is turned off If fan was running at key off it will continue to run for 2 minutes after key is turned off If fan was running at key off it will continue to run for 3 minutes after key is turned off If fan was running at key off it will continue to run for 5 minutes after key is...

Page 4: ...om gauge setup will be lost when reset to factory presets 1 Turn key off 2 Press and hold SW1 and SW2 and turn key on 3 Display will read for reset 4 Display will flash to indicate unit is reset Factory reset values are listed at the beginning of the setup portion of this manual Checking set up diagnostic mode This unit comes with a feature to allow you to mimic normal operating temperatures using...

Page 5: ...ery Shorten fan delay time to prevent excessive battery drain Fan turns on late or not at all Unit has no power Broken shorted wire to sender Wrong gauge is selected gauge setup Wrong sender used for no gauge setup On temperature in setup is too high Fan not connected properly Alternator overcharging Analog gauge applications only With key on hold SW1 if the display doesn t show a temperature afte...

Page 6: ...must include a copy of the dated sales receipt from your place of purchase Send no money We will bill you after repair Dakota Digital 24 Month Warranty DAKOTA DIGITAL warrants to the ORIGINAL PURCHASER of this product that should it under normal use and condition be proven defective in material or workmanship within 24 MONTHS FROM THE DATE OF PURCHASE such defect s will be repaired or replaced at ...

Reviews: