background image

 

 

MAN#650063 

Setting the warning limits and sender setup: 

 

The SND terminal is used to enter and change the warning settings.  Make sure the sensor is disconnected from 

the gauge before attempting to enter setup.  You will need a wire connected to the SND terminal that can be momentarily 
grounded while you watch the gauge.  The headlights should be off or the DIM terminal unhooked so that it does not 
interfere with the setup. 
1.  To enter the set mode, turn the key on with the SND wire disconnected from the sensor and not grounded.  The gauge 

will display “SEt”.  

2. 

Ground the SND wire.  The gauge will display “F” for Fahrenheit or “C” for Celsius.  (If you wait too long the gauge will 
exit the setup routine and you will need to repeat step #1). 

3.  Release the SND wire.  Each time you momentarily ground the SND wire the temperature unit will change. 
4. 

When the desired unit value is displayed, keep the SND wire grounded for about 2 seconds.  The gauge will display “ 
HI”. 

5.  Release the SND wire.  The gauge will display a number between 121 - 229 (50 - 110°C). 
6.  Each time you momentarily ground the SND wire the number will change. 
7.  When the desired high warning value is displayed, keep the SND wire grounded for about 2 seconds.  The gauge will 

display “LO”. 

8.  Release the SND wire.  The gauge will display a number between -36 - 71 (-38 - 22°C). 
9.  Each time you momentarily ground the SND wire the number will change. 
10.  When the desired low warning value is displayed, keep the SND wire grounded for about 2 seconds.  The gauge will 

display “--”. 

11.  Turn the key off. 

 
Troubleshooting guide. 

 

Problem   

 

Possible cause 

 

 

Solution   

 

 

 

 

 

 

Gauge will not light up 

PWR terminal does not have power. 

Connect to a location that has power. 

 

 

 

GND terminal does not have a good 

Connect to a different ground location. 

 

 

 

  ground. 

 

 

 

Gauge is damaged.  

 

Return gauge for service.  (see instructions) 

 

 

 

Gauge lights up, but does 

Loose connection on SND terminal. 

Reconnect wire. 

  not read correctly.   

Poor ground connection. 

 

Move ground to different location 

 

 

Gauge sender setup is incorrect. 

See “Setting sender setup” in the manual. 

 

 

 

Improper sensor location. 

 

Move sensor to a different location. 

 

 

 

Voltage or wiring problem in the 

Check wiring harness for loose or damaged wires. 

 

 

 

  vehicle wiring harness. 

   

 

 

 

 

 

 

 

 

Gauge lights up, but displays  Gauge is damaged.  

 

Gauge must be returned for service.  (see instructions) 

  

“Er0”. 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

Gauge lights up, but displays  SND terminal is shorted to ground. 

Check wire for damaged insulation.  Replace if necessary. 

  

“---”. 

 

 

Sender is damaged. 

 

Replace sender. 

 

 

 

 

 

 

Gauge lights up, but displays  Sender is not connected to gauge. 

Connect SND terminal on gauge to sender terminal. 

  

“EEE”.   

 

Wire between gauge and sender is 

Test and replace wire. 

 

 

 

  broken. 

 

 

 

Sender is damaged. 

 

Replace sender. 

 

 

 

Gauge is damaged.  

 

Return gauge for service.  (see instructions) 

 

 

 

Gauge lights up, but displays  Gauge is sender setup needs to be 

See “Setting sender setup” in the manual. 

  

“Er4”. 

 

 

  reset. 

 

 

 

 

 

 

 

 

 

 

 

Gauge lights up, but displays  Gauge warning points need to be  

See “Setting the warning limits” in the manual. 

  

“Er5”. 

 

 

  reset. 

 

 

 

 

 

 

 

 

 

 

 

Gauge flashes constantly. 

Warning limits are not set properly. 

Reset warning limits. 

 

 

 

Temperature is too high or too low. 

 

 

 

 

 

 

 

 

Gauge will not dim.   

DIM terminal is not connected correctly. Check wiring connections. 

 

 

 

 

 

Gauge remains dim at all 

DIM terminal is getting power  all 

Connect DIM wire to location that only has power when the headlights 

  times. 

 

 

  of the time. 

 

 

  are on. 

 

 

 

Battery is very low.   

 

Recharge or replace vehicle battery. 

 

 

 

Gauge is damaged.  

 

Return gauge for service.  (see instructions) 

 

 

 

 
Technical specifications 

Minimum operating voltage 

7 volts 

Maximum operating voltage 

17 volts 

 

(operating at or near maximum voltage for an extended time can damage unit) 

Maximum temperature reading  - 

255

F (125

C) 

Gauge Resolution 

 

1

F (1

C) 

Gauge accuracy 

 

2

F (

1

C) 

High Warning Range 

 

121 - 229 (50 - 110°C) 

Low Warning Range 

 

-36 - 71 (-38 - 22°C) 

Typical current draw (@ 13.8V)  - 

0.1 A 