4
MAN# 650051-A
TEMP UNIT
The temp unit is set by holding the switch when the “TEMP UNIT” message is displayed
until the display dims and is released. The current unit will be displayed, F or C. Press and
release the switch to toggle the unit. When the desired unit is displayed, press and hold the
switch until the display dims to save the value. Release the switch to continue with setup.
TEMP WARNING SETUP
The temp warning point can be set from 229 – 312
°
F. Press and hold the switch when
“HI WARN” is displayed. Once the display dims release the switch and the current warn value
will be displayed. Press and release the switch to select the desired warn value. Once the
desired value is displayed press and hold the switch until the display dims, then release the
switch to continue with setup. If the warn point is reached/exceeded the display will flash and
the Warning output will be switched to ground.
EGT SETUP
The EGT setup is similar to the Temp setup. The reading can be either Fahrenheit or
Celsius.
EGT UNIT
The temp unit is set by holding the switch when the “TEMP UNIT” message is displayed
until the display dims and the button is released. The current unit will be displayed, F or C.
Press and release the switch to toggle the unit. When the desired unit is displayed, press and
hold the switch until the display dims to save the value. Release the switch to continue with
setup.
EGT WARNING SETUP
The temp warning point can be set from 1150 – 1770
°
F (620 – 1770
°
C). Press and
hold the switch when “HI WARN” is displayed. Once the display dims release the switch and the
current warn value will be displayed. Press and release the switch to select the desired warn
value. Once the desired value is displayed, press and hold the switch until the display dims,
then release the switch to continue with setup. If the warn point is reached/exceeded the
display will flash and the Warning output will be switched to ground.
SETUP DONE
When setup is complete, press and hold the switch when “SETUP DONE” is displayed,
then release when the display dims. The gauge will return to normal operation mode using the
new setup values.
Returning the gauge to factory presets can also be done. To do this the dim terminal will be
used.
1.) Start with the gauge off.
2.) Disconnect the wire from the dim terminal.
3.) Hold the switch while you turn the key on, but DO NOT start the engine. The display
should light up and show “SET MODE”.
4.) Release the switch.
5.) Now apply 12 volts to the dim terminal for the rest of the set up.
6.) Press and release the switch to toggle through the following menus:
“BOOST” “BOST CAL”, “HI WARN”, “HI WARN2”, “UP DATE”; “TEMP” “UNIT”,”HI
WARN”;”EGT””UNIT”, “HI WARN”.
7.) The next menu will say “PRESET”.
8.) Press and hold the switch until the display dims, then release the switch and “SETUP”
”DONE” will be displayed. The factory presets are now loaded and saved.
9.) Press and hold the switch until the display dims to return to normal gauge operation.