Troubleshooting quick tips: 

While the BIM is operating, the dot in the upper left corner of the display will indicate the status.  On steady indicates 
the accessory power is on but not receiving any bus activity.  Flashing slowly indicates it is communicating on the bus.  
If the switch is pressed while the accessory power is off the dot will flash rapidly until the switch is released. 
To see the sensor and channel status on the BIM display, press and hold the switch while the accessory power is on.  
The display will cycle through two screens.  The first will show the BIM inpu

t status.  ‘

’ indicates there is a bus ID 

conflict on that channel ID.  ‘

’ indicates that it is connected properly.  If the input is turned off the digit will be blank. 

The second screen will show the ID assigned to it. 

 

 

Troubleshooting guide. 

Problem   

 

Possible cause 

 

 

Solution   

 

 

 

 

 

Sensor does not show on 

BATT terminal does not have power. 

Connect to a location that has constant battery power. 

  gauge readout. 

 

ACC terminal does not have power. 

Connect to a location that has switched accessory power. 

  BIM will not light up at all. 

GND terminal does not have a good 

Connect to a different ground location. 

  ground. 

 

 

 

Module is damaged. 

 

Return for service.  (see instructions) 

 

 

 

Sensor does not show on 

Interface cable is not connected. 

Connect the supplied 3.5mm data cable between the BIM unit and  

  gauge readout. 

 

 

 

 

 

  the gauge control box. 

  BIM has a steady dot lit 

Interface cable is loose. 

 

Make sure both ends of the cable are seated in securely. 

 

 

 

On VHX systems, the BIM display  

Follow instructions in VHX manual to enable the BIM display screen. 

 

 

 

  for this channel is disabled. 

   

 

 

Another BIM is set with the same  

Test module works when connecte

d to control box alone.  Change ID’s 

   

 

 

 channel IDs. 

 

 

  on one of the modules so each module uses unique IDs. 

 

BIM display shows “



:

” 

Data cable is damaged. 

 

Inspect and replace 3.5mm data cable. 

 

 

 

Another module on the bus is damaged  Inspect other modules on the data bus. 

 

 

 

  or connected improperly. 

 

 

 

 

 

 

 

 

 

Summary of Contents for BIM-16-1

Page 1: ...ck running and the accessory input powers the bus interface port There are two interface I O ports on the module Either one can be connected to the gauge system or to another module allowing several units to be daisy chained together Do not connect the I O port to anything other than a Dakota Digital gauge or BIM Do not mount the module in the engine compartment it should be mounted in interior of...

Page 2: ...AN followed by the number of BIM channels detected Release SW1 If 0 is shown check all connections and then press and hold SW1 with SCAN shown to retry reading the modules Otherwise if any other number is shown press and release SW1 until SETUP is shown Press and hold SW1 until the speed display shows or the message changes Release SW1 On the VFD3 systems the message display will show the label as...

Page 3: ...inal does not have power Connect to a location that has constant battery power gauge readout ACC terminal does not have power Connect to a location that has switched accessory power BIM will not light up at all GND terminal does not have a good Connect to a different ground location ground Module is damaged Return for service see instructions _ Sensor does not show on Interface cable is not connec...

Page 4: ...efective in material or workmanship for the lifetime of the original vehicle it was installed in such defect s will be repaired or replaced at Dakota Digital s option This warranty does not cover nor extend to damage to the vehicle s systems and does not cover diagnosis removal or reinstallation of the product This Warranty does not apply to any product or part thereof which in the opinion of the ...

Reviews: