To change between Air / Fuel and lambda readings: 

 

Turn the key on so the gauge and BIM-13-2 are powered. 

 

Press and hold the setup/status switch on the BIM-13-2.  The status light will slowly flash red and green. 

 

After about 10 seconds the status light will begin flashing rapidly.  Release the switch. 

 

The reading will now be changed. 

 
To set or change the ID number: 
 

The ID will not normally need to be changed.  A green-red-red flash on the BIM-13-2 status light indicates an ID 

conflict with another connected BIM.  The following procedure will allow the BIM-13-2 to automatically select a new, 
unused ID. 

 

Press and hold the setup/status switch on the BIM-13-2 while turning the key on.  The BIM status light will be 

steady RED. 

 

Release the switch.   

 

When the status light begins flashing, it is finished.  

  
This module does not use warning points, so the warning setup is used to program the display range matching 
your wide band controller analog output.  These settings are changed on the gauge system display.  Common 
settings are listed on the front page of the manual. 
Only VFD3/3X controls with a plastic case support adding BIM’s. 
For VFD3, VFD3X, and VHX systems follow these steps: 

 

Make sure the BIM units are all connected to the gauge control box. 

 

Hold the SW1 switch from the gauge system control box while turning the key on.  The message display should 
show SETUP. 

 

Release SW1. 

 

Press and release SW1 until BIM is shown on the message display. 

 

Press and hold SW1.  The message display should show SCAN followed by the number of BIM channels 
detected.  Release SW1. 

 

If 0 is shown, check all connections and then press and hold SW1 with SCAN shown to retry reading the modules. 

 

Otherwise, if any other number is shown, press and release SW1 until SETUP is shown. 

 

Press and hold SW1 until the speed display shows “ – ” or the message changes. 

 

Release SW1.  On the VFD3 systems the message display will show the label assigned to the first channel found 
and the speed display will show “C” followed by the channel ID number.  On the VHX systems the message 
display will show “CH” followed by the channel ID number on one line and the label currently assigned on the 
second line. 

 

Press and release SW1 until the desired channel ID number is shown. 

 

Press and hold SW1.  The message display will show “LABEL”. 

 

Release SW1.  The message display will show the label assigned to this channel. 

 

This label cannot be changed, so press and hold SW1.  The message display will show “WARN”. 

 

Release SW1.  The message display will show “L” followed by the current 0 volt display setting. 

 

Press and release SW1 to change the 0 V display setting to the desired value. 

 

Press and hold SW1 until the speed display shows “ – ”. 

 

Release SW1.  The message display will show “H” followed by the current 5 volt display setting. 

 

Press and release SW1 to change the 5 V display setting to the desired value. 

 

Press and hold SW1.  The message display will now show “DONE”. 

 

This can be repeated for additional channels, or the key can be turned off to exit setup. 

Summary of Contents for BIM-13-2

Page 1: ... gauge system or to another module allowing several units to be daisy chained together Do not connect the I O port to anything other than a Dakota Digital gauge or BIM Do not mount the module in the engine compartment it should be mounted in interior of the vehicle Each unit connected to the bus needs a unique ID number assigned to it The unit comes preset with an ID value that should not conflict...

Page 2: ... release SW1 until BIM is shown on the message display Press and hold SW1 The message display should show SCAN followed by the number of BIM channels detected Release SW1 If 0 is shown check all connections and then press and hold SW1 with SCAN shown to retry reading the modules Otherwise if any other number is shown press and release SW1 until SETUP is shown Press and hold SW1 until the speed dis...

Page 3: ...cates the BIM is currently selected in the gauge setup menu A green red red flash indicates an ID conflict with another connected BIM Troubleshooting guide Problem Possible cause Solution _ Sensor does not show on PWR wire does not have power Connect to a location that has power gauge readout GND wire does not have a good Connect to a different ground location BIM will not light up at all ground P...

Page 4: ...efective in material or workmanship for the lifetime of the original vehicle it was installed in such defect s will be repaired or replaced at Dakota Digital s option This warranty does not cover nor extend to damage to the vehicle s systems and does not cover diagnosis removal or reinstallation of the product This Warranty does not apply to any product or part thereof which in the opinion of the ...

Reviews: