Bus Interface Module for Haltech Engine Management
setup/status switch
BIM-01-2-HAL
Bridge Module for HALTECH Systems
www.dakotadigital.com
605-332-6513
INPUT
BIM-xx-2 power & data connectors.
Either one can be used.
BIM-xx-2 18 inch power/data harness
Connect directly to
another BIM-xx-2
Connect to the BIM-01-2
if you need to connect to a
BIM-xx-2
Connect to the
BIM-01-2
4 PIN HAL CAN
connector
Haltech adapter harness
This Bus Interface Module is designed to read engine information from specific Haltech CAN bus enabled devices. These
kits include Elite series ECU, Elite 1500 or Elite 2500. The module is connected to the Haltech device through the 4-pin
Haltech connection plug on the main harness.
There are two interface (I/O) ports on the module. Either one can be connected to the gauge system or to another
module, allowing several units to be daisy chained together. Do not connect the I/O port to anything other than a Dakota
Digital gauge or BIM. Do not mount the module in the engine compartment; it should be mounted in interior of the vehicle.
The engine and transmission information that is available from the unit depends on the Haltech module programming and
add-ons.
Available readings: engine RPM, vehicle speed, engine coolant temperature, intake/manifold air temperature, oil
pressure, fuel pressure, A/F ratio, MIL, trans temp, MAP pressure, boost, fuel level.
A GPS-50-2 CANNOT be linked (daisy chained) to a BIM-01-2 with a BIM cable.
The two units cannot talk to the display control box at the same time.