Daken M803927 Owner'S Manual Download Page 12

Operation – Important Safety Information

Now that you have completed and tested your assembly, there is some important safety and health 

information you need to know with regard to handling and spraying chemicals.

WARNING

Carefully read and make sure you understand the following safety information before 

using the pump.

General Chemical Safety:

WARNING

Pesticides are hazardous chemicals.

Heed the warnings below and follow all instructions carefully.

Improper handling of chemicals can result in serious injury or illness, or cause damage to the 
environment.

Chemical label

. ALWAYS READ and FOLLOW all chemical label instructions.

Licensing/regulation

. Refer to any applicable licensing restrictions or state/federal regulations

with regard to the application of the particular chemical you plan to use.

Emergency procedures

. Before handling chemicals, carefully review the “Chemical Accident

Procedures” listed later in this section, as well as the “Statement of Practical Treatment” on the
chemical label.

Inhalation/contact

. ALWAYS take precautions to avoid inhaling or coming into contact with

the chemical.

Personal protective equipment

. ALWAYS wear protective clothing, eye protection, and 

chemical-resistant gloves when operating and cleaning the pump. Wear additional protective 
gear (such as facemask or apron) as recommended on the chemical label.

Children/pets

. Pesticides can be especially toxic to children and animals. ALWAYS exercise 

extra caution around children. Keep pump and all spray materials away from children and 
animals.

Ventilation

. ALWAYS ensure there is adequate ventilation when mixing, pouring, or spraying.

Flammables

. NEVER use any flammable chemicals in the pump.

Corrosives

. DO NOT use corrosive chemicals in the pump. They can weaken the pump and its

parts, resulting in leaks. Check with the chemical manufacturer to ensure chemical is
compatible with all components of the pump.

Chemical interaction

. ALWAYS flush the pump before switching chemicals. Different 

chemicals may interact dangerously with each other.

Chemical storage

. ALWAYS store pesticides in a properly labeled container and in a secure 

location per the manufacturer’s recommendations.

Health monitoring

. Monitor the health of operators who are frequently exposed to pesticides, 

as recommended by the chemical label or local/federal regulations.

12

Summary of Contents for M803927

Page 1: ...injury or illness to the operator or nearby persons animals or could cause damage to the environment This pump is recommended for use in spraying non flammable liquids such as pesticides water for pl...

Page 2: ...Hazard Signal Word Definitions 2...

Page 3: ...our Check and test completed assembly 11 Operation Important Safety Information Operation 12 General Chemical Safety Chemical Applicator Safety Chemical Accident Procedures Preparing the Pump for Each...

Page 4: ...zed form or for use with fumigants In addition to spraying pesticides this pump may be used to spray other non flammable liquids Example uses include watering plants trees or spraying water for dust c...

Page 5: ...label WEAR protective clothing eye protection and chemical resistant gloves when operating the pump Wear additional protective gear such as facemask or apron as recommended on the chemical label EXER...

Page 6: ...Personal contamination can occur when chemicals splash spill or spray directly onto a person 1 Immediately follow First Aid instructions on chemical label General procedures can include a Eyes immedia...

Page 7: ...143001507 D5BP 9349143001514 D8BP 9349143001521 D11BP 9349143001538 D15BP 9349143001545 D20BP 9349143001552 D26BP 9349143001569 Daken 3 8 LPM 1 0 GPM Pump 7 WARNING DO NOT PUMP FLAMMABLE FLUIDS DO NOT...

Page 8: ...Inside diameter 3 4 19mm Inside diameter D3BP 3 4 Quick Connect 3 8 9 5mm Inside diameter 3 8 9 5mm Inside diameter NOTE Daken does not recommend the use of metal fittings or rigid pipe to plumb the i...

Page 9: ...with water and neutralize with baking soda 2 Electrical requirements The pump should be on a dedicated individual circuit controlled with a double pole switch UL CSA certified rated at or above the fu...

Page 10: ...ot in a vehicle WARNING Always connect in this sequence to avoid possible shock D3BP D5BP D8BP D11BP D15BP D20BP Positive red wire Negative black wire D26BP Positive red Negative black 4 Disconnect af...

Page 11: ...er modify the pump design 1 Check assembly Check assembly to assure the pump is properly assembled and in safe working condition 2 Test with water Test the system for leaks with water a Fill the tank...

Page 12: ...or coming into contact with the chemical Personal protective equipment ALWAYS wear protective clothing eye protection and chemical resistant gloves when operating and cleaning the pump Wear additional...

Page 13: ...al manufacturer Excess pesticide can be dangerous to humans damage desirable plants and contaminate soil and water sources Children pets ALWAYS exercise extra caution when spraying near areas accessib...

Page 14: ...water or follow directions as specified on the chemical label c Clothing remove contaminated clothing immediately Dispose of heavily contaminated clothing per the instructions on the chemical label fo...

Page 15: ...terials like ground corncobs or pet litter should be spread on the spill area to soak up the pesticide The contaminated material should then shoveled into a leak proof container Do not flush the spill...

Page 16: ...n a safety hazard or poor operation of the sprayer 1 Ensure clean system Ensure the pump has been thoroughly flushed and drained of all residual chemicals from prior uses 2 Inspect repair Inspect and...

Page 17: ...ea Clear the work area of all bystanders and pets Restrict access by the public for the period recommended on chemical label Step Two Operate the pump WARNING ALWAYS wear personal protective equipment...

Page 18: ...er to the pump b Relieve system pressure 6 Discontinue use if clogged or inoperative If the pump becomes clogged or inoperative during use discontinue use immediately DO NOT attempt to service while c...

Page 19: ...ide is to be stored for future use Store all unused pesticide in its original or a suitably marked container in a secure location out of the reach of children animals b If remaining pesticide is to be...

Page 20: ...our RV antifreeze into the pump system Note RV antifreeze is non toxic and biodegradable and generally safer for the environment than automotive antifreeze 2 Spray briefly Turn on the pump and run the...

Page 21: ...protective equipment as directed on the chemical label while servicing your pump 2 Review troubleshoot ing table Review the Troubleshooting Table below for the type of problem you are experiencing Ho...

Page 22: ...fittings Replace cracked fittings Worn diaphragm Replace diaphragm assembly Worn valves Replace valve plate assembly Inlet Outlet tube restriction Remove restriction Incorrect voltage Check voltage 10...

Page 23: ...384 Model Number Electrical connection Maximum amp draw Maximum flow Maximum pressure Ports Overall dimensions Weight D3BP 12 VDC 4 Amps 1 0 GPM 3 8 LPM 40 PSI 2 8 bar 3 4 Quick connect 7 3 x 3 9 x 3...

Page 24: ...ect fittings are compatible with D3BP D8BP D11BP D15BP D20BP and D26BP Part Description 787212 Quick Connect x 3 8 Hose barb elbow 787213 Quick Connect x 1 2 Hose barb elbow 787215 Quick Connect x 1 2...

Page 25: ...2 791634 Base plate assembly 1 3 790576 Diaphragm assembly 1 4 790584 Valve plate assembly 1 5 790589 Upper housing assembly 1 6 791635 Pressure switch assembly 1 7 788429 Quick connect clip 2 8 A268...

Page 26: ...ly 1 2 800428 Base plate assembly 1 3 794988 Diaphragm assembly 1 4 794989 Valve plate assembly 1 5 787015 Quick connect clip 2 6 787011 Upper housing assembly 1 7 786953 Pressure switch assembly 1 8...

Page 27: ...1 3 788017 Diaphragm assembly D11BP 1 788018 D15BP 788019 D20BP 4 788015 Valve plate assembly All 1 5 787012 Upper housing assembly All 1 6 788689 Pressure switch assembly All 1 7 787015 Quick connec...

Page 28: ...2 790016 Base plate assembly 1 3 788019 Diaphragm assembly 1 4 788015 Valve plate assembly 1 5 787012 Upper housing assembly 1 6 788689 Pressure switch assembly 1 7 789252 Relay cover 1 8 788929 Rela...

Page 29: ...6 Motor assembly 1 2 800428 Base plate assembly 1 3 797013 Diaphragm assembly 1 4 798397 Valve plate assembly 1 5 797105 Upper housing assembly 1 6 797407 Pressure switch assembly 1 7 A26815152 Comple...

Page 30: ...to be replaced or repaired is the sole decision of Daken NOTE Some services performed by parties other than Daken may void warranty This warranty covers parts only It will not provide for replacement...

Page 31: ...648 384 or email sales clarkfarmequipment com au Operating 8 30am 5pm Monday to Friday Product Technical Support Call us on Toll Free 1800 817 366 or email support clarkfarmequipment com au Operating...

Reviews: