background image

FUNCTIONAL DESCRIPTION AND SPECIFICATIONS

Disconnect the tool from the air source before making any adjustments, changing accessories o  storing the tool. Such 

precautionary safety measures reduce the risk of unintentional tool operation.

r

FIG. 1

Adjustable Exhaust 

Deflector

Air Cap

Body

Plastic Cover

Nail Indicator

Magazine

Hand Grip

Trigger

Air Plug

3

WARNING

SPECIFICATIONS

Product Size:

Weight: 

Normal Operating Pressure: 

Magazine Capacity: 

Firing Mode:

Fastener Size Range:

Length - 12.99"(330mm)

Height -10.51"(267mm)

Width - 2.99"(76mm)

3.52Ibs(1.6kg)

70-110PSI(0.5-0.75MPa)

100 Nails

 Sequential Fire

                     18 Gauge Brads: 5/8"-1-5/8"(15-40mm)

                     18 Gauge Staples: 1/2"-1-5/8"(13-40mm)

Fastener Type

                  

Quick 

Release Lever 

Magazine 

Latch

Plastic Screw

Flooring Plate

Flooring Nose Cover

5/8"
3/4"
1"
1-3/16"
1-1/4"
1-5/8"

15mm
20mm
25mm
30mm
32mm
40mm

1.26 x 1.05mm

(0.050")(0.041")

18Ga.

1.26 x 1.05mm

(0.050")(0.041")

18Ga.

13mm
16mm
19mm
25mm
32mm
40mm

1/2"
5/8"
3/4"
1"

1-1/4"
1-5/8"

Summary of Contents for XMKC40/9040III

Page 1: ...USERS MANUAL MODEL XMKC40 9040III Failure to follow warning could result in DEATH OR SERIOUS INJURY WARNING M0519 03 13 V1 4 IN 1 BRAD NAILER STAPLER FLOORING NAILER...

Page 2: ...ATURES WORK AREA PERSONAL SAFETY TOOL USE ANDCARE SERVICE AIR SOURCE CONTENTS JAM CLEARING CLEANING STORAGE HOOKUP INSTRUCTIONS FOR TOOL TO AIR SUPPLY IMPORTANT INFORMATION EXPLANATION OF THE NAILING...

Page 3: ...LWAYS WEAR EAR AND HEAD PROTECTION USE SAFETY EQUIPMENT DRESS PROPERLY STAY ALERT WATCH WHAT YOU ARE DOING AND USE COMMON SENSE WHEN OPERATING A POWER TOOL AVOID UNINTENTIONAL FIRING DO NOT OVERREACH...

Page 4: ...the firing head The tool can fire when re connected to an air supply The fasteners can be driven or a way from the workpiece hit someone 1 Doing maintenance and inspection 2 Turning the adjuster and...

Page 5: ...CIFICATIONS Product Size Weight Normal Operating Pressure Magazine Capacity Firing Mode Fastener Size Range Length 12 99 330mm Height 10 51 267mm Width 2 99 76mm 3 52Ibs 1 6kg 70 110PSI 0 5 0 75MPa 10...

Page 6: ...ATION Follow the instructions below to prepare your tool for operation All tool operators and their immediate supervisors must become familiar with the operator safety instructions before operating th...

Page 7: ...gainst the workpiece Pull the trigger 2 Hold the trigger back while separating the safety from the wood The tool will remain in operated status the driver blade will remain at the bottom 3 Remove the...

Page 8: ...he tool in cold conditions the tool will cycle slower than usualwhile driving the first nails The cycle rate will increase as the toolwarms up Keep tool warm to avoid reduced cycle rate DO NOT USE A F...

Page 9: ...or FIG 14 CHANGE THE NOSE COVER The tool is packed with another Regular nose cover with which the nailer can be changed to be regular brad nailer stapler Disconnect the toolfrom air resource Remove fa...

Page 10: ...a etc may damage plastic parts and o rings CLEANING WARNING Do not attempt to clean by inserting pointed objects through openings Sharp edges may damage internal components causing a serious hazard Ve...

Page 11: ...2 Piston is broken or worn 3 Bent fasteners 4 Dirty magazine 5 Loose magazine 6 Wrong fasteners 1 Tighten screws 2 Install overhaul kit 1 Tighten screws 2 Install overhaul kit 1 Make sure the air comp...

Reviews: