The expansion tank vapor output (water discharge) is used to expel  the water 
vapor caused by pressure from the stove. The water vapor expels by taking a line 
from vapor output (water discharge) to the wet floor. 

CAUTION! When filling, the installation  has to be carried out from any point of the 

installation other than the expansion tank and the other outlet on the side should 

be closed with a blind plug, but the vapor output (water discharge) on the 

expansion tank must not be closed. 

While adding water to the expansion tank, please check the water level, fill the 

water up to half of the expansion tank.  

 

4.2.2 Circulation Pump 

Circulation pump and bypass line should be installed to the input of the radiators 

of  the product as shown in (figure). The unshielded cable

,

 located at the (rear) 

part of the product, should be connected to the circulation pump as shown below. 

 

 

4.2.3 Mechanical Thermostat

 

Your stove is equipped with a mechanical thermostat. Appropriate settings of the 

mechanical thermostat is specified in the enclosed information page. In the stand-

by, you can save fuel and take advantage of optimal fuel energy if the 
recommended settings are adhered to. 

While Burning Stove

: (Mechanical Thermostat Settings) 

 

Summary of Contents for D-17

Page 1: ...Installation Manual Central Heating Stove With Solid Fuel Model D 17 Tested according to DIN EN 13240 For product efficiency and emission values see the declaration of conformity TR ...

Page 2: ... Mechanical Thermostat 7 4 2 4 Indicator Panel 8 4 2 5 Hot water for USE 9 4 2 6 Chimney Connection 9 4 2 7 Radiator Installation Connection 9 5 STOVE WORK PRINCIPLES 10 5 1 SUITABLE FUEL 10 5 2 FIRST USE OF STOVE 10 5 3 COMBUSTION AND HEATING 11 5 3 1 Adding fuel 11 5 3 2 Use during transition period 11 5 3 3 Ashtray Discharge 12 5 3 4 Emission Limit 12 6 CLEANING AND MAINTENANCE 12 6 1 PROBLEM A...

Page 3: ...duct ensures that the circulation pump prevents automatically thus avoids the continuous consumption of the electricity Circulation pump works quietly and the electricity consumption is up to a light bulb Once the air flow is set the system automatically starts getting fresh air through the mechanical thermostat Thus fuel savings can be ensured by using the product in the desired degree You have a...

Page 4: ...AINST FREEZING MUST BE TAKEN INTO CONSIDERATION All the required standard examinations are tested for the product The predicted parameters associated with combustion efficiency and exhaust gas emissions are observed The stove type described in this manual has been tested according to the BA 1 DIN 1881 EN13240 standards by an approved agency Combustion chamber cover should be opened only to load th...

Page 5: ...he best possible way However the stove or its accessories may still be damaged during transport Therefore after removing the stove from the package check whether it is complete and undamaged In case of any damage notify your dealer 4 1 SAFETY DISTANCES MINIMUM DISTANCE While installing the stove the fire regulations and chimney s instructions must be complied For any related questions please ask t...

Page 6: ... inner edge of the fire chamber cover You can order the floor protection plate from seller when you require 4 2 STOVE INSTALLATION AND CONNECTION Product installation and assembly should be done according to the user manual and by an authorized person Since our central heating stove with solid fuel for a flat is designed for interior and provide heat to the ambient it should not be installed in ba...

Page 7: ... the expansion tank please check the water level fill the water up to half of the expansion tank 4 2 2 Circulation Pump Circulation pump and bypass line should be installed to the input of the radiators of the product as shown in figure The unshielded cable located at the rear part of the product should be connected to the circulation pump as shown below 4 2 3 Mechanical Thermostat Your stove is e...

Page 8: ... you can set the Mechanical Thermostat to the required temperature it should not be under 40ºC otherwise it will not cause rapid combustion 4 2 4 Indicator Panel Electric Lamp The electric lamp starts to last the moment we plug the stove into the wall socket If this lamp illuminates it indicates that there is electricity If the lamp does not illuminate check the power line Pump the pump lamp indic...

Page 9: ... the chimney When the distance is short at least 1meter length flue pipe must be used and must be installed vertically The chimney to be used at the exhaust gas outlet can be multiple chimney connection See Chimney Assembly Diagram CAUTION Do not burn the stove when the flue pipe is connected First of all the radiator installation must be done Otherwise stove burned without water can lead to stove...

Page 10: ...mbustion is listed in the attached information sheet CAUTION Since wood is not a permanently combustible fuel it is impossible to heat overnight CAUTION Never use wallpaper chipboard waste plastic or treated wood paint coating etc for heating Otherwise the chimney and flue pipes may be blocked Caution Do not use flammable materials thinner paint gasoline etc 5 2 FIRST USE OF STOVE After the instal...

Page 11: ...e If you burn it carefully you will prevent the formation of cracks in the insulating stones damage the paint and deterioration of the material The smell caused by the protective paint on the stove is short lived so keep the doors and windows open CAUTION Our products should not be used to burn environmentally hazardous waste 5 3 1 Adding fuel In addition to suitable fuel enough chimney extraction...

Page 12: ...rding to the Ministry of Environment Applications are for example Wood that is moist and treated with protection Thin sawdust Paper and paperboard except ignition Bark and hardboard waste Plastic and other wastes Burning these materials will damage the environment as well as shorten the life of the stove and cause damages Regular cleaning and maintenance will also reduce harmful emissions 6 CLEANI...

Page 13: ...assembly scheme The boiler does not reach the desired temperature Check Fuel Type Chimney emission may be low Check the combustion chamber for sufficient air supply The desired temperature is not reached while the boiler is burning Check the height of the expansion tank Check plumbing Heat losses are prevented In case of necessity isolation should be done There is no fresh air flow from outside Ve...

Page 14: ...duct our company will try to repair this damage as soon as possible within the warranty period or it will replace the problematic part Only spare parts approved or supplied by the manufacturer must be used After the warranty period our company will continue to serve you in the necessary conditions You are kindly requested to inform the relevant dealer where you have purchased the product from with...

Page 15: ...Product Information Page Central Heating Stove With Solid Fuel D 17 Tested according to DIN EN 13240 ...

Page 16: ... Grate 3 Lateral Sheat 1 mm 16 Ash tray 4 Ceramic Glass 17 Mechanical thermostat vent cover 5 Cover Handle 18 Chimney connection 6 Glass cleaning vent 19 Serpantine output 7 Mechanical thermostat 20 Serpantine input 8 Ash tray 21 Thermostatic valve and expansion tank output 9 Ash cover handle 22 Radıator Cold Water Output 10 Bottom plate 23 Mechanical thermostat 11 Serpantine 24 Radiator hot water...

Page 17: ... the air vent cover widely Approximately after 15 20 minutes the stove will be hot enough Then you can set the mechanical thermostat according to your needs It should not be below 40ºC otherwise moist can occur in the flue pipe and clogge the pipes Fuel Max Fuel Quantity Mechanical thermostat Air passing through the grate Glass Cleaning Air Condition Wood 3 4 Pcs of Wood approx 3 5 4 kg Set the te...