Daitsu CDV-L1 Installation And User Manual Download Page 17

User’s Manual of Remote Controller

 

14 

In unit on status, receiver light board or wired controller is defaulted to display set 

temperature. Press TEMP button to view indoor or outdoor ambient temperature. 

When 

is  displayed,  it  means  the  displayed  temperature  is  indoor  ambient 

temperature. 

When 

is  displayed,  it  means  the  displayed  temperature  is  outdoor  ambient 

temperature. 

Ambient  temperature  displaying  will  be  exited  after  5s  and  then  set  temperature 

will be displayed. 

2.3 Introduction of special functions 

(1). 

Setting child lock 

1). 

Press ▲ and ▼ button simultaneously to lock the buttons on remote controller 

and

  is displayed. 

2). 

Press ▲ and ▼ button simultaneously again to unlock the buttons on remote 

controller and 

is not displayed. 

3). 

If the buttons are locked, 

blinks 3 times when pressing the button and any 

operation on the button is invalid. 

(2). 

Setting low-temperature dehumidifying 

Under dry mode and when set temperature is16

, press ▼ button twice to enter 

low-temperature  dehumidifying  function  and  set  temperature  is  displayed  as  12

.  If 

low-

temperature  dehumidifying  function  has  been  set,  press  ▲  button  to  exit 

low-temperature dehumidifying function and set temperature is displayed as 16

Note: 

If energy-saving function is turned on, low-temperature dehumidifying function is 

invalid. 

(3). 

Absence function 

1). 

Press CLOCK and TEMP button simultaneously to enter absence function. 

Temperature displaying zone displays 8. 

2). 

Press CLOCK and TEMP button simultaneously again to exit absence 

function. Temperature displaying zone resumes previous display. 

3). 

In winter, absence function can keep the indoor ambient temperature above 

0

 to avoid freezing. 

Note: 

Absence  function  is  only  available  in  heating  mode  and  it  will  be  exited  when 

switching mode.

 

(4). 

Setting of master mode indoor unit 

In fan mode, set master mode indoor unit through ▲ and ▼ button: 

Summary of Contents for CDV-L1

Page 1: ...R00 SERIE CDV L1 CDV 1F REMOTE CONTROLLER Models CDV L1 CDV 1F EDITION IM UM En INSTALLATION MANUAL USER MANUAL...

Page 2: ...ce center as soon as possible and provide the following information Content on the nameplate model number cooling capacity production code ex factory date Malfunction details before and after the malf...

Page 3: ...function 2 1 4 Introduction of special functions 6 1 5 Replacing batteries in remote controller and notes 7 2 Remote Controller CDV L1 8 2 1 Preparation before operation 9 2 2 Introduction of operatio...

Page 4: ...User s Manual of Remote Controller 1 1 Remote Controller CDV F1 1 1 Button name and function introduction...

Page 5: ...tion 13 TON Set timer on function 14 Set left right swing status 15 FAN Set fan speed 16 Set temperature and time 1 2 Preparation before operation When using the remote controller for the first time o...

Page 6: ...swing function Setting left right swing 1 Under simple swing status press button to adjust left right swing status 2 Under fixed angle swing status press button to adjust left right swing angle circul...

Page 7: ...tdoor ambient temperature When is displayed it means the displayed temperature is setting temperature When is displayed it means the displayed temperature is indoor ambient temperature When is display...

Page 8: ...ction In unit on status press I FEEL button to turn on or turn off I FEEL function When is displayed I FEEL function is on When is not displayed I FEEL function is off When I FEEL function is turned o...

Page 9: ...eration on the button is invalid 2 Switching temperature scale In unit off status press MODE button and button simultaneously to switch temperature scale between and 3 Setting energy saving function I...

Page 10: ...ed 1m away from the TV set or stereo sound sets The operation of remote controller should be performed within its receiving range If you need to control the main unit please point the remote controlle...

Page 11: ...Button name and function introduction No Button name Function 1 ON OFF Turn on or turn off the unit 2 FAN Set fan speed 3 Set temperature and time 4 MODE Set operation mode 5 Set quiet function 6 Set...

Page 12: ...the time of the system according to current time in the following steps 1 Pressing CLOCK button is blinking 2 Pressing or button the clock time will increase or decrease rapidly 3 Press CLOCK button a...

Page 13: ...and fan modes or when quiet function is on turbo function is invalid Under dry mode fan speed is low and can not be adjusted 4 Setting swing function Setting left right swing 1 Under simple swing stat...

Page 14: ...on is set setting auto quiet function will cancel turbo function 6 Setting health function In unit on status press button to turn on or turn off health function 1 When is displayed health function is...

Page 15: ...timer off 1 Pressing TIMER OFF button OFF is blinking and time displaying zone displays the timer time of last setting 2 Press or button to adjust the timer time 3 Press TIMER OFF button again to con...

Page 16: ...ep curves Notes Sleep function can not be set in auto fan mode and floor heating modes When turning off the unit or switching mode sleep function is cancelled If turning on sleep function auto quiet f...

Page 17: ...the button is invalid 2 Setting low temperature dehumidifying Under dry mode and when set temperature is16 press button twice to enter low temperature dehumidifying function and set temperature is di...

Page 18: ...operation mode 3 Press or button to set the desired temperature temperature setting is not needed in auto mode 4 Press FAN button to set fan speed in auto low medium and high speed 2 5 Replacing batte...

Page 19: ...mally please take the batteries out and reinsert them after 30 seconds If it still can t operate properly replace the batteries If you need to control the main unit please point the remote controller...

Page 20: ......

Reviews: