10
AC Operation
①
Start the engine.
②
Plug in the appliance.
Do not exceed the current limit specified for any one receptacle.
If an overloaded circuit for a long time causes the receptacle to burn.
Most motorized appliances require more than their rated wattage for startup.
If overloaded of the generator the circuit breaker is off, reduce the electrical load on the
circuit and then push to reset circuit breaker.
Battery Charge
The generator has DC outlet for charging a 12 Volt battery. It provides up to 12V-8.3A
(100W) of power.
Be sure to make the correct connection to the battery. You should connect
red of the battery cable with the battery terminal.
If do not correct connect to the battery the DC circuit breaker is off. Reconnect to the battery
and then push to reset circuit breaker.
Do not use AC and DC power at the same time.
High Altitude Operation
At high altitude, the standard carburetor air-fuel mixture will be excessively rich.
Performance will decrease, and fuel consumption will increase.
Engine horsepower will decrease approximately 3.5% for each 1,000 foot increase in
altitude.