Lumination
®
(Tetra
®
PowerGrid - Series)
Installation Guide
3
Install Modules
2” (51 mm)
from edge
2.77” (70 mm)
between columns
Lay modules into the application at least 2 inches (51 mm)
from the edges.
Fasten down each module with at least one screw
in the center hole or two opposing sides.
1
Start another row with 2.77-inch (70 mm) spacing between
the module strings.
Continue this process until the entire application is
populated with modules.
2
Using the diagram below as an estimation guide, begin cutting strings of modules to create 8-inch (203 mm) tall
rows and 12-inch (305 mm) wide columns.
Modules should be 2 inches (51 mm) from the edge of the application with 2.77 inches (70 mm) between
each column.
2
Typical layout
12” (305 mm)
wide columns
2” (51 mm)
from edge
2” (51 mm)
from edge
8” (203 mm)
tall
rows
2.77” (70 mm)
between
columns
2” (51 mm)
from edge
2.77” (70 mm)
between columns