background image

-5-

IV. Particular sheet of explosion diagram

S/N

Part name

Qty. S/N

Part name

Qty.

1

Meter head

1

33

Welding part of left upright pole

1

2

M6X25 hexagon socket head cap bolt

4

34

M10 small flat gasket

21

3

M6 flat shim

4

35

Bulkhead of upright pole

6

4

Screen

1

36 M10X30 round head hexagon socket screw

4

5

Safety switch

1

37

M8X16 hexagon socket pan head screw

6

6

Front drum

1

38

Decorative element at lower left of the

meter

1

7

M8X45 hexagon socket head cap bolt

1

39

M4×10 round head tail-cut tapping screw

4

8

Upper protective cover

1

40

M4X8 flat head screw

18

9

Upper edge strip

2

41

Decorative element at lower right of meter

1

10

Running belt (tire tread)

1

42

DC motor

1

11

Rear drum

1

43

M8×30 hexagon socket head cap bolt

4

12

M8X75 hexagon socket head cap bolt

2

44

φ18×1.5 flat shim

4

13

φ8×1.6 flat gasket

9

45

Spring shim

4

14

High-density running plate

1

46

M10×45 hexagonal screw

1

15

Edge strip at right side

1

47

DC motor base

1

16

Right regulating box

1

48

Motor cushion

4

17

Left regulating box

1

49

M10X40 hexagon socket pan head screw

1

18

Universal foot pad

2

50

Lifting motor

1

19

Edge strip at left side

1

51

M10X95 hexagon socket pan head screw

1

20

M10X70 hexagon socket pan head

screw

2

52

Plastic shim

2

21

M10 self-locking nut

6

53

M10×85 hexagonal screw

22

Erector welding part

1

54

Decorative element of right upright pole

1

23

Castor

2

55

Rubber belt of motor

1

24

M10X58 hexagon socket pan head

2

56

Upper strip block piec

2

25

Dust cover

1

57

M8X45 crossed countersunk head screw

2

26

Motor’s bottom cover

1

58

Support column of running plate

1

27

Left upright pole decorative element

1

59

Shock pad

6

28

Lower control

1

60

M8X25 crossed countersunk head screw

6

29

Front protective cover

1

61

Edge strip positioning buckle

6

30

One-piece switch

1

62

Tabletting of edge strip

2

31

Welding part of right upright pole

1

63

M4X12 flat head screw

2

32

M10X20 round head hexagon socket

screw

4

64

Welding part of GT5D treadmill frame

1

Summary of Contents for GT5Ds

Page 1: ...GT5Ds DC Commercial Motorized Treadmill...

Page 2: ...eadmill and ensure your safety it is forbidden for overweighed beyond the weight limit persons to use the treadmill and for two or more persons to use one treadmill simultaneously 6 Please do not walk...

Page 3: ...Floor area 200 86 150cm Effective usable floor area 146 52cm Features 3000W DC motor Double safety protection functions with both emergency stop and soft stop PU handrail Multi windows LED display Pr...

Page 4: ...n Safety switch Right armrest Right upright pole Upper protective cover Upper edge strip Running belt Right regulating box Treadmill frame Left regulating box Edge strip at left side Erector Left upri...

Page 5: ...roduct explosion diagram 1 2 3 4 5 7 6 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 33 34 35 36 37 38 40 41 42 43 44 45 46 47 48 49 50 51 54 55 57 58 59 60 61 62 64 32 52 63 3...

Page 6: ...gonal screw 1 15 Edge strip at right side 1 47 DC motor base 1 16 Right regulating box 1 48 Motor cushion 4 17 Left regulating box 1 49 M10X40 hexagon socket pan head screw 1 18 Universal foot pad 2 5...

Page 7: ...trol line in the right upright pole with that at the lower right of the meter head secondly insert the meter head into the left and right upright poles finally lock the meter head on the left and righ...

Page 8: ...e figure below Step VI Carefully check if each part of the treadmill is tightened Run the treadmill at the slow speed and check if the each part of the running belt is flexibly rotated and whether the...

Page 9: ...hen it counts down to 0 the treadmill steadily slows down stops operation and displays End It enters into standby state when it fully stops operation for 5 seconds 2 4 Speed Window Displays the curren...

Page 10: ...ncline Incline Standby state used to adjust the set value It is used to adjust the slope in the running state and its adjustment amplitude value is 1 segment time When it is continuously pressed and h...

Page 11: ...stop key to stop the treadmill 4 4 Built in programs Press program switch key select any one of built in programs of P01 P12 At this time the distance calorie window displays program numbers P01 P12...

Page 12: ...am key in standby state until the user defined program U01 U03 you want to run is reached and press the start key after the running time is set Pressing the start button can also start immediately aft...

Page 13: ...or female and provides the basis for people to adjust their weight together with other health indicators The ideal FAT should be between 20 and 24 If it is lower than 19 it means too thin If it is bet...

Page 14: ...to the corresponding position of electronic meter 1 2 Before the powering inspect whether the power ground wire is well grounded and pull the running belt with hands to check whether it can run flexib...

Page 15: ...umber of sparks so the treadmill should be placed at a drafty place and kept away from explosives 2 3 When the treadmill is used ensure its fore and rear feet reliably contact the ground If the ground...

Page 16: ...with the special lubricant The lubrication should not be excessive It is recommended that a 30ml bottle of special lubricating oil for the treadmill should be used for ten times 2 3 Lubricating metho...

Page 17: ...tributed to following reasons 5 1 The treadmill body is placed unevenly 5 2 While exercising on the treadmill the user fails to run on the central position of the running belt 5 3 The strength of user...

Page 18: ...l cannot be received by the drive E13 communication fault the drive signal cannot be received by the Electronic meter A The signal lines of the electronic meter is not well plugged or poor connection...

Page 19: ...orth the strength The breath should be coordinating with the actions In case of short breath stop exercising immediately Frequency The training for the same muscle should be carried out at the interva...