1-1  TECHNICAL SPECIFICATIONS

BSVQ100PV18

BSVQ160PV18

BSVQ250PV18

Power input 
(nominal) 

Cooling

kW

0.005

0.005

0.005

Heating

kW

0.005

0.005

0.005

Casing

Material

Galvanised steel

Dimensions

Unit

Height

mm

207

207

207

Width

mm

388

388

388

Depth

mm

326

326

326

Weight

Unit

kg

14.0

14.0

15.0

Outdoor Unit

Liquid (OD)

Type

Brazing connection

Diameter

mm

9.5

9.5

9.5

Gas

Type

Brazing connection

Diameter

mm

15.9

15.9

22.2

Discharge Gas

Type

Brazing connection

Diameter

mm

12.7

12.7

19.1

Indoor Units

Liquid (OD)

Type

Brazing connection

Diameter

mm

9.5

9.5

9.5

Gas

Type

Brazing connection

Diameter

mm

15.9

15.9

22.2

Sound absorbing thermal insulation material

Foamed polyurethane, Frame resisting needle felt

Standard 
Accessories

Item

Installation manual

Attached piping

Insulation pipe cover

Clamps

Notes

In case of connection with a 

20~50 type indoor unit, match 

to the size of the field pipe 

using the attached pipe. 

Connection between the 

attached pipe and the field pipe 

must be brazed.

In case of connecting with 

indoor unit capaicty index 150 

or more and 160 or less, match 

to the size of the field pipe 

using the attached pipe. 

Connection between the 

attached pipe and the field pipe 

must be brazed.

In case of connecting with a 

200 type indoor unit or capacity 

index more than 160 and less 
than 200, match to the size of 

the field pipe using the 

attached pipe. Connection 

between the attached pipe and 

the field pipe must be brazed.

1-2  ELECTRICAL SPECIFICATIONS

BSVQ100PV18

BSVQ160PV18

BSVQ250PV18

Power Supply

Phase

1~

Frequency

Hz

50

50

50

Voltage

V

220-240

Voltage range

Minimum

V

-10%

Maximum

V

+10%

Total circuit

Minimum circuit amps (MCA)

A

0.1

0.1

0.1

Maximum Fuse Amps

A

15

15

15

Notes

Voltage range : units are suitable for use on electrical systems where voltage supplied to unit 

terminal is not below or above listed range limits

Maximum allowable voltage range variation between phases is 2%

MCA / MFA : MCA = 1.25 x FLA

MFA is smaller than or equal to 4 x FLA

Next lower standard fuse rating minimum 15A

Select wire size based on MCA

Instead of a fuse, use a circuit breaker

Summary of Contents for VRVIII Series

Page 1: ...technical data BS box BSVQ P8B air conditioning systems EEDEN08 200 2a...

Page 2: ...Specifications 2 Technical Specifications 2 Electrical Specifications 2 2 Safety device settings 3 3 Options 3 4 Dimensional drawing centre of gravity 4 Dimensional drawing 4 Centre of gravity 6 5 Pi...

Page 3: ...e size of the field pipe using the attached pipe Connection between the attached pipe and the field pipe must be brazed In case of connecting with indoor unit capaicty index 150 or more and 160 or les...

Page 4: ...S BSVQ100 250P8B 2 Safety device settings 3 3 Options 4D057956A BSVQ P8 100 160 250 PC BOARD FUSE 250V 3 15A BSVQ100 250P8 4TW31159 1 NOTE All options are kits OPTION LIST No Item BSVQ100P BSVQ160P BS...

Page 5: ...t s name plate right side of electric box 300 or more Servicing space 65 or more Servicing space 400 or more Servicing space 400 or more Servicing space In case of use Attached pipe Servicing space 50...

Page 6: ...brazing connection 2 HP LP gas pipe connection port 12 7mm brazing connection 3 Liquid pipe connection port 9 5mm brazing connection 4 Gas pipe connection port 15 9mm brazing connection 5 Liquid pipe...

Page 7: ...re of gravity 3 BSVQ100 160PV1 3D058131 In case of the electrical box on the other side of the unit In case of the electrical box on the standard side of the unit BSVQ250PV1 3D058132 In case of the el...

Page 8: ...ctric Expansion Valve EVL Filter Filter Liquid pipe connection port Electric Expansion Valve EVLS Electric Expansion Valve EVH Electric Expansion Valve EVHS Capillary tube HP LP gas pipe connection po...

Page 9: ...nsion Valve Sub Discharge DS1 DS2 Dip Switch Y3E Electric Expansion Valve Sub Suction F1U Fuse T 3 15A 250V Y4E Electric Expansion Valve Main Discharge HAP Flashing Lamp Service Monitor Green Y5E Elec...

Page 10: ...Operation noise differs with operation and ambient conditions 5 In case of other unit operating in the same system operating sound will be generated ever if indoor unit connected to BS unit is stopped...

Page 11: ...ted therein Specifications are subject to change without prior notice Daikin Europe N V explicitly rejects any liability for any direct or indirect damage In the broadest sense arising from or related...

Reviews: