![background image](http://html1.mh-extra.com/html/daikin/vrv-series/vrv-series_engineering-data_3554418015.webp)
13
FXMQ-MFVJU
EDUS39-900B-F10
FXMQ72MFVJU
Cooling
Outdoor air temperature
°FWB
°FDB
62
66
70
74
78
82
86
90
Capacity
MBh
MBh
MBh
MBh
MBh
MBh
MBh
MBh
67
19600
24000
-
-
-
-
-
-
71
19600
24000
27600
-
-
-
-
-
75
19600
24000
27600
34700
-
-
-
-
79
-
24000
27300
34400
-
-
-
-
83
-
-
27300
34000
56500
-
-
-
87
-
-
27000
33700
55900
72600
-
-
91
-
-
27000
33100
55600
72000
84200
-
95
-
-
-
32700
54900
71300
83800
89300
Heating
Outdoor air temperature
°FWB
°FDB
19
23
27
31
35
39
43
51
55
Capacity
MBh
MBh
MBh
MBh
MBh
MBh
MBh
MBh
MBh
22
50700
50700
-
-
-
-
-
-
-
32
-
-
47000
-
-
-
-
-
-
37
-
-
41200
41200
41200
-
-
-
-
42
-
-
-
-
33800
33800
33800
-
-
52
-
-
-
-
-
26300
26300
26300
-
57
-
-
-
-
-
-
18900
18900
18900
Note:
1. The above capacities are based on the following conditions:
Air discharge temperature setting: 64°F for cooling operation,
77°F for heating (factory setting).
Equivalent piping length: 25 ft.
Level difference: 0 ft.
2. The above capacities values are general average values which can be generated by each compressor operation level.
3. A value enclosed in
means rated capacity.
Summary of Contents for VRV Series
Page 1: ...Outdoor Air Processing Unit FXMQ MFVJU EDUS39 900B F10 202103 Engineering Data 60 Hz...
Page 2: ......
Page 7: ...5 FXMQ MFVJU EDUS39 900B F10 3 Dimensions FXMQ48MFVJU 3D065452A Unit in...
Page 8: ...6 FXMQ MFVJU EDUS39 900B F10 FXMQ72 96MFVJU 3D065453A Unit in...
Page 20: ...18 FXMQ MFVJU EDUS39 900B F10 10 Fan Performances FXMQ48MFVJU 3D065649B...
Page 21: ...19 FXMQ MFVJU EDUS39 900B F10 FXMQ72MFVJU 3D065650B...
Page 22: ...20 FXMQ MFVJU EDUS39 900B F10 FXMQ96MFVJU 3D065651B...
Page 26: ......
Page 27: ......