background image

 

250FC

 

Total Heat Exchanger
HRV (Heat Reclaim Ventilation)

 

4P586308-1 — 2019.06

 

Operation manual

 

1

 

C

 

ONTENTS

 

Page

 

Safety cautions .................................................................................. 1

Names of parts .................................................................................. 2

Operation........................................................................................... 2

Maintenance ...................................................................................... 5

Trouble and countermeasure............................................................. 7

Disposal requirements....................................................................... 7

 

S

 

AFETY

 

 

 

CAUTIONS

 

Read the following cautions carefully and use your equipment
properly.

There are safety cautions and tips listed here as follows:

 

VAM150F
VAM250F

 

Total Heat Exchanger

HRV (Heat Reclaim Ventilation)

 

Operation manual

 

HRV – Heat Reclaim Ventilation

 

Before using the DAIKIN HRV, be sure to read this
operation manual thoroughly. If you have any problems or
there is a malfunction, please refer to this operation
manual. Please keep this manual for your future reference
whenever you do not understand how to use it when
something is wrong with the unit during the operation.

 

WARNING

 

Failure to follow these instructions properly may
result in personal injury or loss of life.

 

CAUTION

 

Failure to observe these instructions properly
may result in property damage or personal
injury, which may be serious depending on the
circumstances.

 

NOTE

 

These instructions will ensure proper use of the
equipment.

Be sure to follow these important safety cautions.

Keep these warning sheets handy so that you can refer
to them if needed.

Also, if this equipment is transferred to a new user,
make sure to hand over this user's manual to the new
user.

 

W ELECTRIC SHOCK

 

 

 

 

Before servicing the unit always shut off power,
otherwise electric shock may occur.

 

 

Never inspect or service the unit by yourself.
Ask a qualified service person to perform this work. 

 

 

Always use the air filter.
If the air filter is not used, heat exchange elements will
be clogged, possibly causing poor performance and
subsequent failure.

 

 

Do not change operations suddenly. It can result not
only in malfunction but also failure of switches or
relays in the body.

 

 

This appliance is intended to be used by expert or
trained users in shops, in light industry and on farms,
or for commercial use by lay persons.

 

 

This appliance is not intended for use by persons
(including children) with reduced physical, sensory or
mental capabilities, or lack of experience and
knowledge, unless they have been given supervision
or instruction concerning use of the appliance by a
person responsible for their safety.
Children should be supervised to ensure that they do
not play with the appliance.

 

 

Do not use an HRV or an air suction/discharge grille in
the following places:
-

Places such as machinery plants and chemical 
plants where gas, which contains noxious gas or 
corrosive components of materials such as acid, 
alkali, organic solvent and paint, is generated.

-

Places where combustible gas leakage is likely.
Such gas can cause fire.

-

Places such as bathrooms subjected to moisture.
Electric leak or electric shock and other failure can 
be caused.

-

Places subjected to high temperature or direct 
flame.
Avoid a place where the temperature near the HRV 
unit and the air suction/discharge air grille exceeds 
50°C. If the unit is used at high temperature, 
deformed air filter and heat exchange element or 
burned motor result. Unit ambient temperature 
conditions should be between –15°C and 50°C 
(80% relative humidity or less)

-

Places subjected to much carbon black.
Carbon black attaches to air filter and heat 
exchange element, disabling them.

 

4PEN586308-1_2019_06.book  Page 1  Wednesday, July 10, 2019  10:13 AM

Summary of Contents for VAM250FC

Page 1: ...OPERATION MANUAL VAM150FC VAM250FC Total Heat Exchanger HRV Heat Reclaim Ventilation Ceiling mounted duct type 4PEN586308 1_2019_06 book Page 1 Wednesday July 10 2019 10 13 AM...

Page 2: ...7 6 3 2 1 3 2 6 5 4 3 1 2 4 3 5 4 1 1 1 2 3 5 11 10 7 6 9 8 4 12 17 16 14 13 15 4PEN586308 1_2019_06 book Page 1 Wednesday July 10 2019 10 13 AM...

Page 3: ...use the air filter If the air filter is not used heat exchange elements will be clogged possibly causing poor performance and subsequent failure Do not change operations suddenly It can result not onl...

Page 4: ...tion method When the HRV remote controllers is not connected the Centralized controller controls the operation of the HRV unit Refer to the section Independent operation of the HRV unit using the Cent...

Page 5: ...the main menu 1 Operation Mode Selector button 2 Fan Speed Airflow Direction button 3 Menu Enter button 4 Up button 5 Down button 6 Right button 7 Left button 8 ON OFF button 9 Operation lamp 10 Canc...

Page 6: ...into the room and that of the room air exhausted outdoor is equal For FRESH UP operation If the Fresh up setting is set to Fresh up air supply The volume of outdoor air supplied into the room is large...

Page 7: ...ON The HRV unit can then be operated independently from the air conditioner When the FILTER indication appears on the display clean the filter of the HRV unit Refer to the section Maintenance on page...

Page 8: ...t exchange element Refer to figure 6 Use the vacuum cleaner equipped with a brush on the tip of the suction nozzle Lightly contact the brush on the surface of the heat exchanging element when cleaning...

Page 9: ...it using the air conditioner remote control or centralized controller Refer to Operation on page 2 Check if the indication of operation stand by on remote controller BRC301B61 is shown It indicates th...

Page 10: ...NOTES 4PEN586308 1_2019_06 book Page 1 Wednesday July 10 2019 10 13 AM...

Page 11: ...NOTES 4PEN586308 1_2019_06 book Page 2 Wednesday July 10 2019 10 13 AM...

Page 12: ...4P586308 1 2019 06 Copyright 2019 Daikin 4PEN586308 1_2019_06 book Page 1 Wednesday July 10 2019 10 13 AM...

Reviews: