background image

26

UAT-C_(i) 

Installation

Installation

Installation Guideline

Safety Precautions

This manual provides the procedures of installation to ensure a safe and good standard of operation for the 
air conditioner unit.
Special adjustment may be necessary to suit local requirements.
Before using your air conditioner, please read this instruction manual carefully and keep it for future reference.
This appliance is intended to be used by expert or trained users in shops, in light industry and on farms, or for 
commercial use by lay persons.
This appliance is not intended for use by persons, including children, with reduced physical, sensory or mental 
capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction 
concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.

WARNING

  Installation and maintenance should be performed by

 quali

fi

  ed persons who are familiar with local code and

 regulation, and experienced with this type of 
 appliance.

 All 

fi

 eld wiring must be installed in accordance with the 

  national wiring regulation.

 Ensure that the rated voltage of the unit corresponds 

  to that of the name plate before commencing wiring 
  work according to the wiring diagram.

 The unit must be GROUNDED to prevent possible 

  hazard due to insulation failure.

 All electrical wiring must not touch the refrigerant 

  piping or any moving parts of the fan motors.

 Con

fi

 rm that the unit has been switched OFF before

  installing or servicing the unit.

 Disconnect from the main power supply before 

  servicing the air conditioner unit.

 DO NOT pull out the power cord when the power is 

  ON. This may cause serious electrical shocks which 
  may result in 

fi

 re hazards.

  Keep the indoor and outdoor units, power cable and

  transmission wiring, at least 1m from TVs and radios,  
  to prevent distorted pictures and static. {Depending on 
  the type and source of the electrical waves, static may 
  be heard even when more than 1m away}.

NOTICE

Disposal Requirement

Dismantling of the unit, treatment of the refrigerant, oil and other parts must be done in accordance with the applicable 
legislation.

CAUTION

Please take note of the following important points
when installing.

 

Do not install the unit where leakage of fl ammable

  gas may occur.

If gas leaks and accumulates around the unit, 
it may cause 

fi

 re ignition.

 

Ensure that drainage piping is connected properly.

If the drainage piping is not connected properly, 
it may cause water leakage which will dampen 
the furniture.

 

Do not overcharge the unit.

This unit is factory pre-charged. 
Overcharge will cause over-current or damage 
to the compressor.

 

Ensure that the unit’s panel is closed after service  

 or 

installation.

Unsecured panels will cause the unit to 
operate noisily.

 

Sharp edges and coil surfaces are potential 

  locations which may cause injury hazards. Avoid 
  from being in contact with these places.

 

Before turning off the power supply, set the remote

  controller’s ON/OFF switch to the “OFF” position  
  to prevent the nuisance tripping of the unit.

 If this is 

  not done, the unit’s fans will start turning automatically 
  when power resumes, posing a hazard to service 
  personnel or the user.

 

Do not operate any heating apparatus too close to the

  air conditioner unit.

 

Don’t use joined and twisted wires for incoming

 power 

supply.

 

The equipment is not intended for use in a potentially 

 explosive 

atmosphere.

Summary of Contents for UAT150C

Page 1: ...TECHNICAL MANUAL Packaged Air Conditioner Rooftop C Series UAT C series Cooling only 50Hz R22 ...

Page 2: ......

Page 3: ... 1 Features 2 Fan Performance Chart 6 Fan Performance Table 10 Engineering Physical Data 11 Performance Data 12 Outlines Dimensions 16 Wiring Diagrams 18 Installation 26 Specification Guide 28 Engineering Physical Data Arabic 29 Specification Guide Arabic 30 ...

Page 4: ...ication 9 Mechanical Control PCB Control Power Supply Y1 50Hz 3Ph 380 415V Product Type UAT Rooftop Product Specification Variation G Gold Fin Outdoor Coil Bare Fin Outdoor Coil Size 150 150 000 Btu h 300 300 000 Btu h Product series C C Series G 9 Product Origin X OYLM ...

Page 5: ...for High Ambient Application and capable of operating at an outdoor ambient of up to 54 C Lightweight and compact The lightweight and compact design of UAT C series allows for ease of transportation and installation Separate Service Panels The unit is designed with two separate service panels for easy electrical box servicing Independent Refrigerant Circuit Each unit is designed with two independe...

Page 6: ...r coils are manufactured from seamless inner grooved copper tubes mechanically bonded to aluminium fins to ensure optimum heat transfer All coils are tested against leaks by Nitrogen holding at 609psig and highly precise Helium leak test at 235psig ALL standard coils are up to 3 rows 14 16 FPI 3 8 9 52mm O D tubes Options Hydrophilic Gold Fin coating NA549 condenser coil is offered as option which...

Page 7: ...installed filter Electrical Control Panel The control panel is protected by a panel cover to prevent nuisance changes by unauthorized personnel Two control options are available as factory installed Mechanical Control Mechanical Control option is suitable for wiring with field installed thermostat or building management system The unit is designed where each refrigerant system can be controlled se...

Page 8: ...al control of compressor condenser motor and evaporator motor Intelligent control to ensure balance usage of compressor in the system Auto random restart and memory backup of last setting in case of interrupted power supply Energy saving function Sensor fault indication With the remote wired controller connected the following features can be performed Temperature setting 7 days programmable timer ...

Page 9: ...nce Chart UAT150C 0 100 200 300 400 500 600 700 3600 4100 4600 5100 5600 Air Flow Total Static Pressure Pa 800 700 1000 Internal Static Pressure Standard Point CFM 900 1 5 kW 3 0 kW 1700 1900 2100 2300 2500 2642 L S 1100 1200 1300 1400 RPM 2 2 kW ...

Page 10: ...C 0 100 200 300 400 500 600 700 5200 5700 6200 6700 7200 7700 Air Flow Total Static Pressure Pa 800 700 1000 Internal Static Pressure Standard Point CFM 900 3 7 kW 3 0 kW RPM 2454 2600 2800 3000 3200 3400 3630 L S 1100 1200 1300 1400 2 2 kW ...

Page 11: ...0 100 200 300 400 500 600 700 6500 7000 7500 8000 8500 9000 9500 Total Static Pressure Pa Air Flow UAT240C 800 700 600 Internal Static Pressure Standard Point CFM 900 5 5 kW 3 7 kW 3 0 kW RPM 3870 L S 3270 3470 3070 3670 4480 4070 4270 ...

Page 12: ... 400 500 600 700 800 7000 7500 8000 8500 9000 9500 10000 10500 Total Static Pressure Pa Air Flow UAT300C 800 700 1000 Internal Static Pressure Standard CFM 900 5 5 kW 3 7 kW 3 0 kW RPM 4100 4700 L s 3900 3700 3500 3300 4300 4500 4955 1100 1200 4900 ...

Page 13: ...5 900 Air Flow 7900 CFM ESP 20 200 mmH2O Pa Fan Speed 700 Motor Output kW 3 0 3 0 3 0 3 0 3 0 3 0 3 0 3 0 3 7 3 7 3 7 7900 RPM 540 580 620 660 700 740 780 815 850 890 920 Motor Output kW 3 0 3 0 3 0 3 0 3 7 3 7 3 7 5 5 5 5 5 5 5 5 9500 RPM 630 660 700 730 770 800 830 860 Motor Output kW 3 7 5 5 5 5 5 5 5 5 5 5 5 5 5 5 UAT300C 7000 RPM 580 660 730 790 860 920 980 1030 1140 Air Flow 8700 CFM ESP 25 ...

Page 14: ...N MATERIAL ALUMINIUM FACE AREA m2 0 57 0 65 0 89 1 14 ROW 3 3 4 4 AIR QUALITY FILTER TYPE WASHABLE SARANET QUANTITY pc 2 2 2 2 CASING COLOUR LIGHT GREY CONDENSER SOUND POWER LEVEL dBA 85 87 87 92 SOUND PRESSURE LEVEL dBA 66 68 68 73 UNIT DIMENSION HEIGHT X WIDTH X DEPTH mm 1390 x 1965 x 1630 1390 x 1965 x 1630 1690 x 1965 x 1905 1650 x 2410 x 2030 PACKING DIMENSION HEIGHT X WIDTH X DEPTH mm 1540 x...

Page 15: ...16 74 30 0 C 49 11 42 62 10 60 47 54 41 87 11 32 45 88 41 08 12 15 44 15 40 26 13 09 41 98 38 28 14 17 39 38 35 91 15 47 38 88 35 45 15 89 37 15 33 87 16 76 33 0 C 49 88 49 88 10 64 48 60 48 60 11 38 47 26 47 26 12 24 45 83 45 83 13 21 43 58 43 58 14 31 40 88 40 88 15 62 40 35 40 35 16 04 38 55 38 55 16 92 22 0 C 26 7 C 53 38 27 87 10 86 51 67 27 28 11 59 49 88 26 66 12 43 48 00 26 02 13 38 45 64 ...

Page 16: ... 0 C 62 96 54 64 13 72 60 95 53 68 14 65 58 82 52 66 15 72 56 61 51 61 16 94 54 09 49 32 18 49 51 07 46 57 20 35 49 98 45 57 21 04 47 97 43 74 22 28 33 0 C 63 94 63 94 13 77 62 31 62 31 14 74 60 59 60 59 15 85 58 75 58 75 17 11 56 14 56 14 18 67 53 01 53 01 20 54 51 88 51 88 21 24 49 79 49 79 22 49 22 0 C 26 7 C 68 43 35 73 14 06 66 24 34 97 15 01 63 95 34 19 16 10 61 54 33 36 17 32 58 80 31 88 18...

Page 17: ... 0 C 83 49 75 40 18 65 80 82 74 07 19 91 78 00 72 67 21 37 75 07 71 22 23 03 71 72 68 04 25 43 67 71 64 23 28 31 64 76 61 44 29 24 62 08 58 90 31 16 33 0 C 84 80 84 80 18 72 82 63 82 63 20 03 80 34 80 34 21 54 77 91 77 91 23 25 74 44 74 44 25 68 70 27 70 27 28 58 67 22 67 22 29 52 64 44 64 44 31 46 22 0 C 26 7 C 90 75 49 30 19 11 87 84 48 26 20 40 84 81 47 17 21 88 81 60 46 03 23 55 77 97 43 98 26...

Page 18: ... 22 99 99 62 85 37 24 55 96 14 83 75 26 36 92 53 82 08 28 40 88 58 78 58 30 69 83 84 74 37 33 44 81 92 72 68 34 54 78 76 69 87 36 38 33 0 C 104 52 104 52 23 09 101 85 101 85 24 70 99 03 99 03 26 56 96 03 96 03 28 67 91 93 91 93 30 99 87 01 87 01 33 77 85 03 85 03 34 88 81 75 81 75 36 73 22 0 C 26 7 C 111 85 56 82 23 56 108 27 55 62 25 15 104 53 54 37 26 98 100 58 53 05 29 04 96 29 50 79 31 38 91 1...

Page 19: ...UAT C_ i Outlines Dimensions 16 Outlines Dimensions Model UAT150C Model UAT180C ...

Page 20: ...Outlines Dimensions UAT C_ i 17 Model UAT240C Model UAT300C ...

Page 21: ...18 UAT C_ i Wiring Diagrams Wiring Diagrams Model UAT150C Mechanical Control ...

Page 22: ...19 Wiring Diagrams UAT C_ i Model UAT150C Wired Control ...

Page 23: ...20 UAT C_ i Wiring Diagrams Model UAT180C Mechanical Control ...

Page 24: ...21 Wiring Diagrams UAT C_ i Model UAT180C Wired Control ...

Page 25: ...22 UAT C_ i Wiring Diagrams Model UAT240C Mechanical Control ...

Page 26: ...23 Wiring Diagrams UAT C_ i Model UAT240C Wired Control ...

Page 27: ...24 UAT C_ i Wiring Diagrams Model UAT300C Mechanical Control ...

Page 28: ...25 Wiring Diagrams UAT C_ i Model UAT300C Wired Control ...

Page 29: ...servicing the air conditioner unit DO NOT pull out the power cord when the power is ON This may cause serious electrical shocks which may result in fire hazards Keep the indoor and outdoor units power cable and transmission wiring at least 1m from TVs and radios to prevent distorted pictures and static Depending on the type and source of the electrical waves static may be heard even when more than...

Page 30: ...fer diagram below for the space required around the unit Note that a All dimensions shown are in mm b All space values shown are minimum clearance required for the unit c Unit shown in the diagram is UAT300C Other models shall follow the same clearance ...

Page 31: ...less inner grooved copper tubes mechanically bonded to aluminium fins to ensure optimum heat transfer All coils are tested against leaks by Nitrogen holding at 609psig and highly precise Helium leak test at 235psig Condenser Fan Motor Condenser Motor shall be of IP55 insulation class rating and is equipped with dust proof bearing Condenser fan shall be direct driven propeller type Refrigerant Circ...

Page 32: ... ﺩﻳﺴﻴﺒﻞ 85 87 87 92 ﺍﻟﺼﻮﺕ ﺿﻐﻂ ﻣﺴﺘﻮﻯ A ﺩﻳﺴﻴﺒﻞ 66 68 68 73 ﺍﻟﺠﻬﺎﺯ ﺃﺑﻌﺎﺩ ﺍﻟﻌﻤﻖ ﺍﻟﻌﺮﺽ ﺍﻻﺭﺗﻔﺎﻉ ﻣﻢ 1390 x 1965 x 1630 1390 x 1965 x 1630 1690 x 1965 x 1905 1650 x 2410 x 2030 ﺍﻟﻌﺒﻮﺓ ﺃﺑﻌﺎﺩ ﺍﻟﻌﻤﻖ ﺍﻟﻌﺮﺽ ﺍﻻﺭﺗﻔﺎﻉ ﻣﻢ 1540 x 2150 x 1935 1540 x 2150 x 1935 1865 x 2150 x 2220 1875 x 2590 x 2270 ﺍﻟﺠﻬﺎﺯ ﻭﺯﻥ ﻛﺠﻢ 600 650 850 980 ﺍﻟﻤﺮﻭﺣﺔ ﺍﻟﻨﻮﻉ ﺍﻟﻤﺮﻭﺣﺔ ﺍﻟﺪﻓﻊ ﻣﺒﺎﺷﺮ ﺩﻓﻊ ﺍﻟﻤﺮﻭﺣﺔ ﻣﺤﺮﻙ ﺍﻟﻨﻮﻉ ﺍﻟﺤﺚ IP ﺍﻟﺤﻤﺎﻳﺔ ﻣﺆﺷﺮ IP55 ﺍﻟﻌﺰﻝ...

Page 33: ...ﺰﺍﺕ ﺍﻟﻤﻜﺜﻒ ﻭﻣﻠﻔﺎﺕ ﺍﻟﻤﺮﻭﺣﺔ ﻭﻣﺤﺮﻛﺎﺕ ﺍﻟﻀﻮﺍﻏﻂ ﻣﻦ ﺍﻟﺴﻘﻒ ﻭﺣﺪﺓ ﺗﺘﻜﻮﻥ ﻛﻬﺮﺑﺎﺋﻴﺔ ﻭﻣﻜﻮﻧﺎﺕ ﺍﻟﺘﺒﺮﻳﺪ ﻭﺃﻧﺎﺑﻴﺐ ﺍﻟﺘﻮﺳﻴﻊ ﻭﺻﻤﺎﻣﺎﺕ ﺍﻟﻤﺒﺨﺮ ﻭﻣﻠﻔﺎﺕ R 22 ﺑﻤﺒﺮﺩ ﺑﺎﻟﻜﺎﻣﻞ ﻭﻣﺸﺤﻮﻧﺔ ﺩﺍﺧﻠﻴﺔ ﺑﺄﺳﻼﻙ ﻣﻜﺘﻤﻠﺔ ﺍﻟﻮﺣﺪﺓ ﺗﺠﻤﻴﻊ ﻳﺘﻢ ﺍﻟﺘﺴﻠﻴﻢ ﻗﺒﻞ ﺟﻮﺩﺗﻬﺎ ﻣﻦ ﺍﻟﺘﺤﻘﻖ ﻳﺘﻢ ﻛﻤﺎ ﺻﺎﺭﻣﺔ ﻻﺧﺘﺒﺎﺭﺍﺕ ﻭﺧﺎﺿﻌﺔ ﻣﺤﻴﻄﺔ ﺣﺮﺍﺭﺓ ﺩﺭﺟﺔ ﻓﻲ ﺍﻟﻌﻤﻞ ﻋﻠﻰ ﺑﺎﻟﻘﺪﺭﺓ ﺍﻟﺴﻘﻒ ﻭﺣﺪﺓ ﺗﺘﻤﺘﻊ ﺃﻥ ﻳﺠﺐ ﻋﻄﻞ ﺃﻱ ﺩﻭﻥ ﻣﺌﻮﻳﺔ ﺩﺭﺟﺔ 54 ﻭ ﻣﺌﻮﻳﺔ ﺩﺭﺟﺔ 19 ﺑﻴﻦ ﺗﺘﺮﺍﻭﺡ ﺍﻟﻀﺎﻏﻂ ﺍﻟﺬﻱ ﺍﻟﻤﺨﺮﻭﻃﻲ ﺍﻟﻨﻮﻉ ﻣﻦ ﻳﻜﻮﻥ ﻭﺃﻥ...

Page 34: ...31 Specification Guide ART C_ i ...

Page 35: ...32 ART C_ i Specification Guide ...

Page 36: ......

Reviews: