background image

Non-Programmable 

Owner's

Manual

and
Installation

Instructions

Digital Thermostat

with Humidity Control • Multi Stage 2+2

TSTATD2200C-2

COMMERCIAL

for

Commercial Use

D_TSTATD2200C-2_Manual_HR.pdf   1   8/29/13   1:11 PM

Summary of Contents for TSTATD2200C-2

Page 1: ...rogrammable Owner s Manual and Installation Instructions DigitalThermostat with Humidity Control Multi Stage 2 2 TSTATD2200C 2 COMMERCIAL for Commercial Use D_TSTATD2200C 2_Manual_HR pdf 1 8 29 13 1 1...

Page 2: ...ns 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Follow the Installation Instructio...

Page 3: ...re in the air Differential The forced temperature difference between the heat set point and the cool setpoint Heat Setpoint The coolest temperature that the space should drop to before heating is turn...

Page 4: ...ration INSTALLER SETUP 16 Scrolling Display Options System Runtimes Advanced Setup TECHNICIAN SETUP 29 Advanced OutputTesting EquipmentTesting 19 Backlight Operation 25 26 Troubleshooting Sensor Calib...

Page 5: ...TO SET RST FLTR EMERGCY HEAT DISPLAY ACCESSORY SETUP SERVICE SET CLOCK EMERGCY HEAT DISPLAY ACCESSORY SETUP HOLIDAY PAGE 1 Get to Know Your Thermostat Down Button Override Button Up Button Heat or Co...

Page 6: ...d cooling is turned off RoomTemperature Display Indicates the current room temperature and displays the outdoor temperature when selected The scrolling display will be used to help you easily navigate...

Page 7: ...temperature s Setup Step icon Indicates the step number when the thermostat is in the setup mode icon Indicates the keypad has been locked 2nd Stage icon Indicates what stage of cooling or heating is...

Page 8: ...n Fan On icon Indicates constant continuous fan operation When Fan On is not lit indicates the fan will only operate when necessary to heat or to cool PAGE 4 Get to Know Your Thermostat Display Featur...

Page 9: ...GEOVER MODE Pressing the UP or DOWN buttons in Auto mode will adjust both the heat and cool setpoints simultaneously To adjust heat and cool setpoints individually choose HEAT mode to adjust the heat...

Page 10: ...gain to return to normal operation REMOTE TEMP Press the ACCESSORY button to enter the accessory setup screen Press the UP button to view linked wireless and wired sensors and other accessories Press...

Page 11: ...these step by step instructions If you are unsure about any of these steps call a qualified technician for assistance Remove the cover of the old thermostat If it does not come off easily check for sc...

Page 12: ...at Y2 Y2 H HUM HUM CKGND Ck1 Dry Contact Switch Dry Contact Switch DRY CONTACT DRY CONTACT W1 O B W2 D DEHUM DEHUM 2nd Stage Cooling Humidity Dehumidity Wire Connections Installation Instructions If t...

Page 13: ...W2 W1 O B G Y1 Y2 REMOTE OUTDOOR DRY CONTACT 1st stage heat reversing valve 2nd stage heat circuit Dehumidi er control circuit Humidi er control circuit W2 DEHUM C W1 O B HUM R REMOTE OUTDOOR Y2 Y1 D...

Page 14: ...et for GAS ELEC This jumper J3 controls how the thermostat will control the Fan G terminal in heating mode When GAS is chosen the thermostat will not energize the Fan G terminal in heating When ELEC i...

Page 15: ...used Gas Residential Commercial 1 Stage Cooling with 1 stage Electric Heat 5 Wire 1 Stage Cooling 1 Stage Heat 24VAC Power 24VAC Common 1st Stage Heat 1st Stage Cool Fan Gas Elec O not used Electric...

Page 16: ...t R 24VAC Power C 24VAC Common W1 O B Reversing Valve Y1 1st Stage Compressor Cool or Heat W2 Aux Heat G Fan J1 Heat Pump J2 O J3 Electric Residential Commercial Heat Pump with O Reversing Valve 7 Wir...

Page 17: ...n Terminal on Equipment Dry Contact and Remote or Outdoor Sensor 12 11 10 9 8 7 6 5 4 3 2 1 Time Clock R C DEHUM HUM W2 W1 O B G Y1 Y2 REMOTE OUTDOOR DRY CONTACT R C DEHUM HUM W2 W1 O B G Y1 Y2 REMOTE...

Page 18: ...ING ON Next Press UP to turn on and cycle up through the heating stages Press DOWN to turn the heating stages off Press MODE to exit Press DOWN to turn on and cycle down through the cooling stages Pre...

Page 19: ...ght Level Press the SETUP button then press MODE repeatedly until the Backlight setup step appears Use the UP or DOWN buttons to adjust the brightness Press MODE to advance to the next step Press SETU...

Page 20: ...when a setting change is made Scroll Letters Slow Scroll Letters Fast Scroll Words Slow Scroll Words Fast Scrolling Non Scrolling Whole Words Slow Whole Words Fast Words Centered Slow Words Centered...

Page 21: ...emperature reading is updated once every minute a wireless outdoor sensor s temperature reading is updated once every 5 minutes To initiate the Emergency Heat feature Press and hold the EMERGCY HEAT b...

Page 22: ...e selection Press MODE to advance to the next step Press SETUP to leave the setup screens Setup Step 30 These setup steps allow the user to monitor equipment runtimes and program service alerts Runtim...

Page 23: ...xt setup step Press SETUP again to leave the setup screens How to Change Settings in the Setup Screens Installer Setup Setpoint Limits Setup Step 20 Maximum Heat Setpoint Setup Step 21 35 99 Minimum C...

Page 24: ...times per hour your HVAC unit may energize For example at a setting of 6 cycles per hour the HVAC unit will only be allowed to energize once every 10 minutes The Cycles Per Hour limit may be overridde...

Page 25: ...If set to OFF the following two steps will not appear Max Dehum Overcool Setup Step 44 Specifies how many degrees below the Cool setpoint the air conditioning will run to satisfy a Cool to Dehumidify...

Page 26: ...splay This setting may be used with time clocks or twist timers to force the thermostat from Occupied to Unoccupied FORCE UNOCCUPIED If Force Unoccupied is selected in step 71 when the dry contact is...

Page 27: ...d the MODE button While holding the MODE button press the UP and DOWN buttons together The icon will appear on the display then release the buttons To unlock the keypad press and hold the MODE button...

Page 28: ...nd hold SETUP for 5 seconds All icons will appear on the display H Lo Program ONOFF Outdoor Fan On COOL SET AUXHEAT SET Day Night Morning Evening Setup Step 2nd3rd Stage Am Pm 18 88 188 188 88 188 Aft...

Page 29: ...equipment outputs for testing Calibrate thermostat remote and humidity sensors Control HUM output On or Off Control DEHUM output On or Off Technician Setup contains the following options H Lo Program...

Page 30: ...of proper power REMEDY Make sure the power is on to the furnace and that you have 24vac between R C SYMPTOM The heating does not attempt to turn on CAUSE The heating setpoint is set too low REMEDY Rai...

Page 31: ...ool Setpoint Set Unoccupied Heat Setpoint 2 3 4 6 7 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 38 39 40 41 43 44 56 70 71 72 73 Heat Cool Auto Off Heat Cool Off Heat Off Cool Off On Off Off 7 lev...

Page 32: ...tup Table Df PAGE 28 Humidity Polarity Dehumidify Polarity Press Outdoor To Clear All Messages 75 76 79 Open Closed Open Closed N A Open Open N A 21 21 22 Df Factory Default Setting Pg D_TSTATD2200C 2...

Page 33: ...5 changeover 5 19 fan 4 17 mode 5 19 AuxHeat icon 4 b reversing valve 10 25 Backplate 9 Buttons accessory 1 17 down cooler 1 15 display 1 16 emergency heat 1 17 front panel 1 humidity 1 6 fan 1 4 17 m...

Page 34: ...ce pan 22 override 22 EH 25 Electric Heating AuxHeat icon 2 jumper setting 10 Emergency Heat 17 Factory Defaults caution i settings 27 28 resetting 24 Fahrenheit 21 Fan button 17 on during heat see El...

Page 35: ...oor read to 20 viewing 6 Reset thermostat settings see Factory Defaults runtime fan filter 18 humidify 18 UV light 18 Reversing Valve 10 Runtime resetting see Reset setting humidifier 18 service filte...

Page 36: ...see Reset pan see Dry Contact UV light see Reset Setpoint cool see Cool dehumidification 6 heat see Heat humidification 6 Simplest Operation 5 Technician Setup 14 25 Thermostat Sensor calibrate 14 24...

Page 37: ...F THIS WARRANTY SHALL BE PERFORMED DURING NORMAL WORKING HOURS ALL REPLACEMENT PARTS WHETHER NEW OR REMANUFACTURED ASSUME AS THEIR WARRANTY PERIOD ONLY THE REMAINING TIME PERIOD OF THIS WARRANTY THE M...

Page 38: ...Notes D_TSTATD2200C 2_Manual_HR pdf 42 8 29 13 1 11 PM...

Page 39: ...Notes D_TSTATD2200C 2_Manual_HR pdf 43 8 29 13 1 11 PM...

Page 40: ...Notes Printed on recycled paper P N 88 981 Rev 1 D_TSTATD2200C 2 Manual_p44 pdf 44 9 5 13 12 02 PM...

Reviews: