![Daikin T Sense AX1 User& Installer'S Manual Download Page 6](http://html1.mh-extra.com/html/daikin/t-sense-ax1/t-sense-ax1_userand-installers-manual_3261368006.webp)
T Sense Keypad Quick User & Installer Manual Rev 2.0
INSTALLER PROGRAMMING SHEET
Default Installer Pin 12345
Enter Installer programming mode: [INSTALLER CODE] +
[COM] + [#]
Symbol:
Exit Installer programming mode: Press and hold [*] for 2
seconds
Enable
Back to Installer programming main page: [*]
Disable
x
Unused
PC
Display
Item
Description
Zone Display (Default Setting)
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
Zone Type Setting
01
DELAY
Delay Zone
Zone number ON mean the zone
is assigned as Delay Zone
02
INSTAN
Instant Zone
Zone number ON mean the zone
is assigned as Instant Zone
03
INTER
Interior Zone
Zone number ON mean the zone
is assigned as Interior Zone
04
24 HR
24 Hour Zone
Zone number ON mean the zone
is assigned as 24 Hour Zone
05
LIGHT
Light Zone
Zone number ON mean the zone
is assigned as Light Zone
06
SILENT
Silent Zone
Zone number ON mean the zone
is assigned as silent Zone
Remark : Based on Zone Type Setting’s Table (Refer above table)
-Press the number to toggle the setting
Alarm Delay Setting
07
ENTRY1
Partition 1 Entry
Delay Timer
From 0 to 200 seconds
030#
08
ENTRY2
Partition 2 Entry
Delay Timer
From 0 to 200 seconds
000#
09
EXIT1
Partition 1 Exit
Delay Timer
From 0 to 200 seconds
060#
10
EXIT2
Partition 2 Exit
Delay Timer
From 0 to 200 seconds
000#
11
BELL
Bell Audible Time
From 1 to 30 minutes, 0 =
continuous
005#
Zone Partition
14
ZN
NUM
Individual Zone
Partition
Key in zone number
(01 - 16 #)
Part
Partition
Set 1 for partition 1. 2 for
partition 2.
1#
Zone Sensitivity Setting
16
ZN
NUM
Individual Zone
Sensitivity
Key in zone number
(01 - 16 #)
ZN SEN
Sensitivity level
From 1 to 100.
Sensitivity level x 10ms.
006#
17
P GRP
Zone Pulse Count
Group
Zone number ON mean the zone
is programmed to the zone pulse
count group
18
P CTR
Zone Pulse
Counter
From 1 to 255 times. If counter
exceed, zone pulse count group
will trigger
002#
19
P TMR
Zone Pulse
Counter Reset
Timer
From 1 to 255 seconds. Zone
pulse counter reset timer
090#
5