Removal of Electrical Box / PCBs / Swing Motors
Si041056
14
Removal Procedure
2
Pull out the drain hose.
3
Remove the 2 screws
and detach the swing
motor unit.
In case that you cannot
remove the swing motor unit
easily, remove the auxiliary
piping first. Refer to the
“Removal of Indoor Heat
Exchanger”.
4
Remove the 2 screws
and remove the swing
motor for vertical
blades.
The assembly has 6 hooks.
Step
Procedure
Points
Drain hose
(R11357)
(R13624)
Swing motor
unit
(R13515)
Hook
Swing motor
Hook